INSTALLATION INSTRUCTIONS

STEP 1. Attach the coulter bracket to the planter unit using (3) ½” x 1-1/2” bolts and lock
nuts. Do no fully tighten hardware, coulter blade alignment to the planter opener will need
to be done later.

STEP 2. Attach the 2960-133 arm assembly to the coulter bracket using the 5/8” x 2”
bolts, 1 5/8” flat washer and lock nuts. When the coulter is set to the desired depth, fully
tighten the 5/8” x 2” bolts.