Installation, Table a. sw1 (receive) and sw2 (transmit), Table b. sw3, sw4, and sw5 option settings – ADTRAN 2FXS/DPO PM User Manual

Page 2

Advertising
background image

2

Section 61109403L2-5, Issue 3

61109.403L2-5C

• Tandem or private line automatic ringdown mode with

D3 or D4 signaling.

• Transmit and receive gain/attenuation adjustable in

0.1 dB increments.

• Transmit input range of -4.5 to 1.8 dBm.
• Receive output range of -6.3 to 0.0 dBm.
• Complies with AT&T Publications 43801, 41008,

41009, and Bellcore GR-1089-CORE requirements
for Type 1 Equipment.

• Supports Calling Number Delivery and other common

(CLASS

TM

) service offerings according to TR TSY

000030 section 3.3.1.1.

2.

INSTALLATION

After unpacking the unit, immediately inspect it for
possible shipping damage. If damage is discovered, file
a claim immediately with the carrier and then contact
ADTRAN customer service (see

section 6, Warranty and

Customer Service).

The 2FXS/DPO PM plugs directly into an ADTRAN ACT
2300/1900 or standard D4 channel bank. No installation
wiring is required. To install, grasp the 2FXS/DPO PM by
the faceplate and insert it into the backplane connector
until firmly seated.

Provisioning Options
Most options on the 2FXS/DPO are provisionable either
manually, using internal slide switches, or electronically
using a menu-driven program called EASYMENU. The
trunk processing options are found on internal slide
Switch 7 (SW7) and can only be provisioned manually.

Manual provisioning should be completed before
the 2FXS/DPO is inserted into the channel
bank. Electronic provisioning should be
completed following installation.

Manual Provisioning
Internal slide switches SW1,2, 3, 4, and SW7 are used to
manually provision and set the operational modes and
options of the unit. Figure 1 displays switch locations.

Slide switches SW1 and SW2 are used to set, receive, and
transmit attenuation. Table A displays the available options.

Slide switches SW3-1, 2, 3, 4, and SW3-5 are used to
provision the desired operation mode of the unit.

Slide switch SW4 is used to provision the trunk processing
(SD), dial pulse correction (DPC), loop or ground start (GS),
PLAR mode (PD3), tandem battery mode (TRB), tandem
start mode (TWS), dial tone (DTG), and ringback tone
(RTG).

Slide switch SW7 is used to provision the trunk processing
options: make busy lead (1G), make busy closure (L), and
busy trunk sleeve (S). Table B summarizes the option
settings for SW3, SW4, and SW7.

Impedance

TNDM Mode

PLAR Mode

FXS Mode

DPO Mode

Ringback Tone

Dial Tone

Tandem Mode

Signaling

Tandem Mode

Battery

PLAR Mode

Trunk Type

Start Mode

Dial Pulse

Correction

Busy Trunk

During CFA

Make Busy

Lead 1 Ground

Make Busy

Closure

Busy Trunk Sleeve
Option during CFA

SW3-1

(Z900)

SW3-2

(TNDM)

SW3-3

(PLAR)

SW3-4

(FXS)

SW3-5

(DPO)

SW4-1

(RTG)

SW4-2

(DTG)

SW4-3

(TWS)

SW4-4

(TRB)

SW4-5

(PD3)

SW4-6

(GS)

SW4-7

(DPC)

SW4-8

(SD)

SW7-2

(1G)

SW7-3

(L)

SW7-4

(S)

ON

OFF

On
Off

On
Off

On
Off

On
Off

On
Off

On
Off

On
Off

On
Off

On
Off

On
Off

On
Off

On
Off

On
Off

On
Off

On
Off

900 ohms
600 ohms

Enabled

Disabled

Enabled

Disabled

Enabled

Disabled

Enabled

Disabled

Enabled

Disabled

Enabled

Disabled

Wink

Immediate

Reverse

Normal

D3
D4

Group

Loop

Enabled

Disabled

Enabled

Disabled

Enabled

Disabled

Enabled

Disabled

Enabled

Disabled

Function

Switch

Selection Setting

Trunk Processing

General Parameters

Operational Mode

Table B. SW3, SW4, and SW5 Option Settings

Function

Add Attenuation

0.1 dB

SW1,2 - 6

0.2 dB

SW1,2 - 5

0.4 dB

SW1,2 - 4

0.8 dB

SW1,2 - 3

1.6 dB

SW1,2 - 2

3.2 dB

SW1,2 - 1

Amount in dB

Note 1:

Factory default setting for all switches is "off."

Note 2:

Multiple switch activation causes a cumulative effect
on the amount of attenuation added.

Note 3:

The largest transmit attenuation value in 2-Wire
mode is 6.3 dB.

Activate

Switch to

"On" Position

Selection/Setting

Table A. SW1 (Receive) and SW2 (Transmit)

Attenuation Options.

Advertising