Outback Power Systems FW-X240 Installation Manual User Manual

Page 12

Advertising
background image

11

LOAD L1 120VAC

LOAD L2 120VAC

500

WATTS

4500

WATTS

TO LOADS

500W

TO LOADS

4500W

25 AMP

25 AMP

2500W

2500W

WHITE

WHITE

120V

120V

25 AMP

2000W

2000W

RED

BLACK

X240

AC NEUTRAL BUS

Figure 7: FW-X240 Installation Balancing Two FX Series Inverter/Chargers (OutBack Stacking)*

* Figure 9 shows current fl owing from the L1 FX through the FW-X240 to run in parallel with the L2 FX

output. The L1 inverter is producing almost half of the power required to power the load on L2 and

at the same time is supplying power to its own L1 load.

• When both FXs are awake and producing power, a 240 Volt load will be powered by both inverters

equally.

• If there is less than 1000 watts on L1, then the L2 FX will go to sleep. The FW-X240 is still active and

producing 240VAC.

• A small 240VAC load would be powered from the L1 inverter and the FW-X240.

• A large load turning on will wake up the L2 FX. The L2 inverter will go back to sleep as soon as the

large load on L2 goes away.

Note: Systems with more than four FXs might require two FW-X240s in parallel and require 35 amp

breakers as well.