Outback Power Systems FLEXpower TWO Quick Start Guide User Manual

Components mate3 programming, Led indicators on the inverter, Major components

Advertising
background image

Components

MATE3 Programming

IMPORTANT:

Programming should be done by a qualified installer who is trained on programming inverter power systems. Failure to program accurate parameters for the
system could potentially cause equipment damage. Damage caused by inaccurate programming is not covered by the limited warranty for the system.

AC Source

Utility Grid, or
AC Generator

Main Electrical Panel

(or overcurrent device
for the AC source)

Electrical Distribution Subpanel

(Load Panel)

Battery Bank

Photovoltaic (PV) Array
(with PV Combiner Box)

Customer-Supplied

Components

Contact Technical Support:

Telephone: +1.360.618.4363
Email:

[email protected]

Website:

www.outbackpower.com

IMPORTANT:

Not intended for use with

life support equipment.

> 90% (blinks if charge parameters are met)

Color

Red

Yellow

Yellow

Yellow

Green

≥ 80%

≥ 70%

≥ 60%

≥ 60% off, < 60% solid, < 50% blinks

Battery State-of-Charge

FNDC LED Indicators

Phase

Active

Error

DC

AC IN

AC OUT

Red

Yellow

Yellow

Yellow

Red

Red

Surge Protector LEDs

LED Indicators on the Inverter

Inverter Status LED Indicators

Green

Yellow

Red

Inverter on (solid) or standing by (flash)

AC source in use (solid) or standing by (flash)

Inverter error or warning (see manual)

Green

Yellow

Red

12.5 Vdc or higher

11.5 to 12.4 Vdc

11.4 Vdc or lower

Color

Battery Status LED Indicators

25.0 Vdc or higher

23.0 to 24.8 Vdc

22.8 Vdc or lower

50.0 Vdc or higher

46.0 to 49.6 Vdc

45.6 Vdc or lower

12 V Inverter

24 V Inverter

48 V Inverter

Note: For automatic generator

start features see the MATE3
manual for details.

900-0152-01-00 Rev A.vsd\Page-1\2013-01-17

©2012 OutBack Power Technologies. All Rights Reserved.

Inverter/Chargers
(x2)

AC Enclosure Box

FW500-AC

DC Enclosure Box

FW500-DC

System Display and

Controller

MATE3
MATE2

Communications

Manager

HUB10
HUB4

FX Series
VFX Series
GTFX Series
GVFX Series
GFX Series

FLEXnet DC Monitor FNDC
Surge Protector FW-SP-ACA
Remote Temp Sensor RTS

FLEXpower System Products

Major Components

AC Bypass

Assembly

FW-IOBD-120/240VAC
FW-IOBD-120VAC

PNL-175-DC
PNL-250-DC

Inverter Circuit

Breaker

PV8
PV12

Charge Controller

FLEXmax 80
FLEXmax 60

Optional OutBack

Components

PV Combiner Box

Balancing

Transformer

FW-X240

Advertising