Specifications, Table 10 flexmax settings (mate3) – Outback Power Systems FLEXmax Extreme Owners Manual User Manual

Page 69

Advertising
background image

Specifications

900-0150-01-00 Rev A

67

Table 10 FLEXmax Settings (MATE3)

Mode

Menu Item

Setting

Auxiliary Output

Diversion:Solid St

Default <Off>

<On, Auto, Off>

Relative Voltage

Default 0.0 Vdc

Range: 0.0 to 5.0 Vdc

Hysteresis

Default 0.2 Vdc

Range: 0.0 to12.0 Vdc

Hold

Default 0.1 second

Range: 0.0 to 25 seconds

Delay

Default 0.0 seconds

Range: 0.0 to 24 seconds

Low Batt Disconnect

Default <Off>

<On, Auto, Off>

Disconnect

Default 13.6 Vdc

Range: 10 to 80 seconds

Reconnect

Default14.4 Vdc

Range: 10 to 80 seconds

Disconnect Delay

Default 01 second

Range: 0 to 250 seconds

Remote

Default <Off>

<On, Auto, Off>

Vent Fan

Default <Off>

<On, Auto, Off>

Enable

Voltage

Default 14.4 Vdc

Range: 10. 0 to 80.0 Vdc

PV Trigger

Default <Off>

<On, Auto, Off>

Active

Default Active High

Range: Active High or Active Low

Enable

Voltage

Default 140 Vdc

Range: 20 to150 Vdc

Hold

Time

Default 01.1 second

Range: 0 to 25 seconds

Error Output

Default <Off>

<On, Auto, Off>

Low Battery Voltage

Default 11.5 Vdc

Range: 10 to 80 Vdc

Night Light

Default <Off>

<On, Auto, Off>

Active

Default Active High

Range: Active High or Active Low

Threshold

Default 010 Vdc

Range: 5 to 150 Vdc

ON

Time

Default 4 hours

Range: 00 to 23 hours

Hysteresis Time ON

Default 1 minute

Range: 1 to 255 minutes