Sd card logging, Data log file format, Operation – Outback Power Systems AXS Port SunSpec Modbus Interface Owners Manual User Manual

Page 14: Table 3 charge controller configuration block

Advertising
background image

Operation

12

900-0138-01-00 Rev

B

Table 3 Charge Controller Configuration Block

Start End Size R/W Name

Type

Units

Scale
Factor Contents

Description

48 48 1 R/W

CCconfig_AUX_Divert_
Relative_Volts

int16 Volts

Voltage
_SF

Programmable AUX Divert Relative Volts

49 49 1 R/W

CCconfig_AUX_Divert_
Hyst_Volts uint16

Volts

Voltage
_SF

Programmable AUX Divert Hyst Volts

50 50 1 R

CCconfig_Major_Firmware
_Number

uint16

N/A

N/A

Read Only

Charge Controller Major firmware revision

51 51 1 R

CCconfig_Mid_Firmware_
Number

uint16

N/A

N/A

Read Only

Charge Controller Mid firmware revision

52 52 1 R

CCconfig_Minor_Firmware
_Number

uint16

N/A

N/A

Read Only

Charge Controller Minor firmware revision

53 53 1 W

CCconfig_Set_Data_Log_
Day_Offset

uint16 Days

N/A Write

Only Day

offset 0-128, 0 =Today, 1 = -1 day …

54 54 1 R

CCconfig_Get_Current_
Data_Log_Day_Offset

uint16 Days

N/A Read

Only Current Data Log Day Offset

55 55 1 R

CCconfig_Data_Log_Daily_
AH

uint16

AH

AH_SF

Read Only

Data Log AH

56 56 1 R

CCconfig_Data_Log_Daily_
kWH

uint16 KWH

KWH
_SF

Read Only

Data Log kWH

57 57 1 R

CCconfig_Data_Log_Daily_
Max_Output_Amps

uint16 Amps

Voltage
_SF

Read Only

Data Log maximum Output Amps

58 58 1 R

CCconfig_Data_Log_Daily_
Max_Output_Watts

uint16 Watts

Power_
SF

Read Only

Data Log maximum Output Wattage

59 59 1 R

CCconfig_Data_Log_Daily_
Absorb_Time

uint16 Mins

N/A Read

Only Data Log Absorb Time Minutes

60 60 1 R

CCconfig_Data_Log_Daily_
Float_Time

uint16

Mins

N/A

Read Only

Data Log Float Time Minutes

61 61 1 R

CCconfig_Data_Log_Daily_
Min_Batt_Volts

uint16 Volts

Voltage
_SF

Read Only

Data Log minimum daily battery voltage

62 62 1 R

CCconfig_Data_Log_Daily_
Max_Batt_Volts

uint16 Volts

Voltage
_SF

Read Only

Data Log maximum daily battery voltage

63 63 1 R

CCconfig_Data_Log_Daily_
Max_Input_Volts

uint16

Volts

N/A

Read Only

Data Log maximum daily input voltage

64 64 1 R

CCconfig_Clear_Data_Log_
Read

uint16

N/A

N/A

Read Old

Read value needed to clear data log

65 65 1 W

CCconfig_Clear_Data_Log_
Write_Complement uint16

N/A N/A

Write

Only

Write value's complement to clear data log (not
Implemented)

SD Card Logging

The AXS Port records operational status information about the system. It will record data to the
microSD card up to the limit of the card. (It has been tested with microSD cards up to 8 GB.) The
interval for automatic downloading to the microSD card can be set at intervals from 1 to 60 seconds.
This setting is made in the Outback_SD_Card_Data_ Log_Write_Interval field. The default setting is
0 (disabled).

If the card’s capacity is exceeded, the data will begin to be overwritten starting with the oldest first.

Data Log File Format

As noted on page 3, each OutBack product exports data in comma-separated ASCII strings.

Information generated by this function will be saved on the SD card in a generic .csv file format, which
can be read by most spreadsheet programs. The file name on the .csv file will appear as follows:

Example: 11062722.csv (YYMMDDHR.csv)

Where: YY = Last 2 digits of the year, MM = Month (01-12), DD = Day (01-31), HR = Hour (00-23)

Examples of data logs are shown on the next page.