Operation

900-0009-01-00 Rev

C

45

Figure 34

Miscellaneous Screen #2

GT STATE PWM% ChgT
255 07 50.0 005

EXIT NEXT RSTRT

Misc Screen #1


FORCE
EXIT NEXT FLOAT BULK

To bring the charge controller out of Snoozing mode:

1. Press <RSTRT>.

2. Press <EXIT> to return to the main menu.

Force Bulk/Float Screen

PCB Target BTMP CFB
512 14.4v 255 0712

EXIT BACK

 Press <BACK> to return to the

Force Bulk/Float screen.

 Press <EXIT> twice to return to

the main menu.

PCB

Target BTMP CFB

512

14.4v 255 0712


EXIT BACK

PCB

Target

BTMP CFB

512

14.4v

255 0712


EXIT BACK

PCB Target

BTMP

CFB

512 14.4v

255

0712


EXIT BACK

PCB Target BTMP

CFB

512 14.4v 255

0712


EXIT BACK

PCB represents the temperature of the internal components. It
is used to control the cooling fan. These values are in digital
counts, not degrees. The lower the number, the higher the
temperature. (25°C is approximately a value of 525.)

BTMP is a battery temperature sensor reference value, used to
compensate the charging voltage. The range is 0 to 255. These
values are in digital counts, not degrees.

An X next to this value indicates an external RTS is being used in a
system with a HUB and system display.

The target voltage the controller is trying to reach. This will
depend on the active stage of the charger and the set target
value for that stage.

CFB represents Current FeedBack. This is the output value of the
internal current sensor and is used to calculate output amps and
watts to track the maximum power point of the array.

Misc Screen #2

GT STATE PWM% ChgT
255 07 50.0 005

EXIT NEXT RSTRT

Misc Screen #1

To force the charger into a Bulk or Float charge cycle:

1. Press <NEXT>.

2.

Select either a Float or Bulk charge cycle. Forcing a Float or
Bulk recharge will end an EQ cycle. See page 20 for details on
these modes.
 Press <FLOAT> to force a Float charge.
 Press <BULK> to force a Bulk charge.

3. Press <EXIT> to return to the main menu, or

press <NEXT> to view the next miscellaneous screen.