Default factory dip switch setting, Led pin header, Error led activity led – Addonics Technologies RAID TOWER IX RT93DAHX User Manual

Page 4

Advertising
background image

www.addonics.com

Technical Support (M-F 8:30am - 6:00pm PST)

Phone: 408-453-6212

Email: www.addonics.com/support/query/

Default factory DIP Switch setting:

SW1 – RAID Setting DIP Switch

BZS – Error buzzer function

EZ – Automatic rebuilding to spare drive (one of the drives on the raid is set as a

spare). If EZ is ENABLED anda drive failure occurs, the spare will

automatically act as a drive replacement and rebuilding will automatically

start.

M2 – RAID mode 2

M1 – RAID mode 1

M0 – RAID mode 0

1.

Error buzzer function is ENABLED (BZS) when dip switch is in OFF position

2.

Auto-rebuilding to spare drive is DISABLED (EZ)

3.

Individual drive mode is ENABLED (M0~M2)

Note: When the default factory RAID setting is used, independent drive configuration

and optical drive are supported only when connecting to controllers with Silicon

Image Sil3124, Sil3132 chip set or controllers that are Port Multiplier (PM)

compatible. Simultaneous DVD writing was tested using the Nero Burning Rom.

LED Pin Header

J1 – Drive Activity LED

P5 – Activity LED for eSATA host port lights up when it is connected to a

SATA controller card.

P0, P1, P2, P3 & P4 - Activity LEDs for port 0, 1, 2, 3, 4 & 5 light up when a drive is

connected and blinks when there’s drive activity.

J3 – Error LED

P5 – error LED for eSATA host port

P0, P1, P2, P3 & P4 - error LED for port 0, 1, 2, 3, 4 & 5

J3

J1

Error LED

Activity LED

P5 P0 P1 P2 P3 P4

P5 P0 P1 P2 P3 P4

1 2 3 4 5

SW1

BZS EZ M2 M1 M0

OFF

OFF

OFF

OFF

OFF

Advertising
This manual is related to the following products: