TROUBLESHOOTING



PROBLEM

1. NO PRESSURE












2. PUMP RUNS, BUT LOW
PRESSURE





3. PUMP PRESSURE GOOD BUT

LOW OUTPUT THROUGH
NOZZLES



4. EXCESSIVE VIBRATION or
NOISE








CAUSES & REMEDIES

A. PUMP NOT PROPERLY PRIMED
B. STRAINER STOPPED UP
C. PUMP SUCKING AIR or PUMP HAS

AIR LOCK. CHECK HOSES FOR
CRACKS or HOLES. MAKE SURE
FITTINGS ARE TIGHT.
CENTRIFUGAL PUMP MAY HAVE
AIR LOCK. UNSCREW 1/8” PLUG
FROM TOP UNTIL WATER SHOOTS
OUT OF IT

D. SUCTION LINE SUCKING

TOGETHER – NEED STIFFER HOSE

E. WORN or LEAKING SEALS



A. SUCTION LINE & FITTINGS

STOPPED UP or HOSE KINKED

B. WORN ROLLERS or IMPELLAR
C. STOPPED UP STRAINER




A. NOZZLE SIZE MAYBE TOO SMALL.

CHECK CALIBRATION & GALLONS
PER ACRE

B. OUTLET LINE TOO SMALL or

BLOCKED OFF

C. BY-PASS OPEN TOO MUCH. CLOSE

A LITTLE MORE



A. POSIBLE LOOSE COULER –

DAMAGED SHAFT

B. EXCESSIVE PTO or ENGINE SPEED
C. IMPELLAR or INTERNAL PROBLEM