Placing in storage, Removing from storage – Ag Spray Equipment LA9000 Liquid Applicator User Manual

Page 3

Advertising
background image

A G S P R A Y . C O M 2

g. Remove nozzles from boom Disassemble and

wash nozzle, Spring, diaphragm and housing.

Store inside.

4. Lubricate all grease points. Make sure all grease

cavities have been filled with grease to remove

any water residue from the washing.

5. Inspect all the hydraulic hoses, couplers and fittings.

Tighten any loose fittings. Replace any hose that

is badly cut, nicked, abraded or is separating from

the crimped end of a fitting.

6. Inspect all the spray hoses and fittings. Tighten any

loose fittings. Replace any hose That is badly

cut, nicked, abraded or is separating from a fitting.

7. Touch up all paint nicks and scratches to prevent

rusting.

**STORAGE SAFETY**

1. Store unit in an area away from human activity.

2. Do not permit children to play on or around the

stored applicator.

3. Unhook and store in the transport configuration.

At the end of the spray season, the machine should be thor-

oughly inspected and prepared for storage. Repair or replace

any worn or damaged components to prevent any unnecessary

down time at the beginning of the next season. Follow this

procedure:

1. Thoroughly wash the machine using a hose or a

pressure washer to remove all dirt, mud, debris or

residue.

2. Thoroughly wash the inside of the tank.

3. In climates that encounter freezing temperatures

during the storage period, the following

preparation should be done:

a. Add 10 gallons (40 liters) of a potable RV

antifreeze to the tank.

b. Run unit for 5 minutes in the spray cycle to

circulate solution to all parts of the circuit.

c. While circulating the fluid, open and close all the

valves in the system to flush all the water from

the system.

e. Flush the solution out the booms.

f. Open all disconnects and drain hoses, pumps,

filters, solenoids and tanks.

PLACING IN STORAGE

When removing from storage and preparing to use,

follow this procedure.

1. Clear the area of bystanders, especially small

children, and remove foreign objects from the

machine and the working area.

2. Check

a. Tank for cracks

b. Tank hold down hardware

c. All hardware. Tighten as required.

d. Tire pressure.

e. All sprayer and hydraulic lines, fittings and

connections. Tighten as required.

REMOVING FROM STORAGE

3. Lubricate all grease fittings.

4. Replace any defective parts.

5. Fill the tank with 20 gallons (75 liters) of clean water

and run for 5 minutes. Open and close all valves

several times. Flush water through the booms.

6. Repeat step 5.

7. Calibrate the pump, nozzles and sprayer before using.

8. Go through the pre-operation checklist before using.