Ag Spray Equipment LA5000 Liquid Applicator User Manual

Page 5

Advertising
background image

3. Connect wiring harness if using hydraulic pump with rate

control.

4. Grease Applicator (Refer to Mainentance).

5. Before road travel, install all locking collars on toolbar

cylinders and safety pins on wings.

6. Remove locking collars as needed to maintain a depth of

4 to 5 inches. Constant down pressure on main lift is not

recommended (weight of toolbar will keep unit in the ground).

Leave hydrualic selector in neutral for field operation.

7. Remove safety pins on wing cylinders. Wing cylinders remote

will run in constant while down (Figure 7).

The Applicator is equipped with adjustable down pressure relief

valve on wing cylinders. The valve is preset at 800 PSI. This may

be adjusted as needed. The relief valve is located under tongue,

and requires an allen wrench to adjust (clockwise to increase

pressure and counterclockwise to decrease pressure.) (Figure 8).

8. After unfolding main wing, engage hydraulic lever in “constant

pressure.” This is necessary to allow wings to maintain

constant depth and follow uneven terrain, as well as the ability

to “gullwing” (Lift both wings evenly when turning. See #9).

9. Field Operation: When you come to the end of the field.

1. Lift main section

2. Pull back on main wing lever long enough to lift both

wings slightly (“gullwing”).

3. After turning, lower main section and wing section

and return wing hydraulics to constant pressure.

10. Check and clean screens as needed.

11. Pump Settings

Optional Ground Drive Pump

11a - Remove tranport pin

11b - Use John Blue pump setting slide chart. Loaded radius is

9.75 and sprocket ratio is 32 drive and 18 driven.

11c - Set pump to recommended setting.

Optional Hydraulic Drive Pump

a. Hydraulic pump hoses supplied on the applicator

include (1) 1/2” line and (1) 3/4” line. The 1/2” hose

is the hydraulic supply (in/pressure) and the 3/4”

hose is the return (out/non-pressure).

NOTE: It is recommended for optimal pump performance that

the 3/4” return line connect directly to the tractor hydraulic

reservoir (not tractor SCV port). Doing so eliminates possible

back pressure restriction on the 3/4” return line. Excessive

back pressure restriction can cause hydraulic orbital motor

damage/failure.

b. Proper hydraulic pump disengagement. When shutting off

the pump, move the selector to the FLOAT position to allow

the centrifugal pump to come to a gradual stop. Standard

spool valves, which are found on all tractor hydraulic systems,

can cause potentially damaging high peak pressures in the

hydraulic system when closed, because of abrupt shutoff of

oil flow in both the supply and return lines.

c. Close and lock down the bypass adjusting screw in the

hydraulic motor (if applicable).

Switch rate controller to manual and press the “+” button on

TeeJet or “Increase” button on Raven, hold for 8 seconds. Then

press the “-” button on TeeJet or “Decrease” button on Raven for

4 seconds.
Set the tractor hydraulic flow control valve for minimum hydraulic

oil flow to the remote outlet (Tortoise position).
Start the tractor and allow the hydraulic oil to circulate for

approximately 10 to 15 minutes or until adequately warmed.
Prime the centrifugal pump with all valves open.
Open the sprayer control regulating valve and the boom shut-off

valves.
Slowly adjust the tractor hydraulic flow control valve until the

desired boom pressure is attained.
NOTE: See manufacture pump operators manual for further

setup and maintenance.

7

6

8

A G S P R A Y . C O M 4

Advertising