TROUBLESHOOTING GUIDE

PROBLEM

REASON

SOLUTION

Discharge Outlet Leak

a. Debris caught in the Rolling Seal
b. Debris caught between the Air & Vacuum

Seal and the Body.

c. Torn or cracked Rolling Seal and/or Air &

Vacuum Seal.

Perform:
PERIODIC MAINTENANCE

Discharge Outlet Broken

Air valve was hit or mishandled.

Unscrew and replace.

Upper Drain Outlet

Upper Drain Outlet plugged with debris and
won't drain the accumulated water.

Clean the hole with a pin and clean running
water or a burst of air.

MAINTENANCE INSTRUCTIONS D-43

EnM-D43-2-12

PARTS LIST

No. Part

1.

Discharge Outlet

2.

O-Ring

3.

Body

4.

Float and Seal Assembly

4a.

Air & Vacuum Seal

4b.

Air Release Rolling Seal

5.

Float Lock

6.

Upper Drain Outlet

Upper Component

Air Release Rolling Seal