Pin assignment - i/o connector led indicators – Axis Communications Q8108-R User Manual

Page 7

Advertising
background image

AXIS Q8108-R User’s Guide

Page 7

ENGL

IS

H

Pin assignment - I/O connector

LED indicators

Pin
number

Function

Notes

Specifications

1

Output 1

Open collector NPN transistor with the emitter
connected to ground when activated.
Outputs are reserved for developer use.

Max load = 500mA

2

Output 2

3

Input 1

Inactive for voltages less than 1V
Active for voltages more than 3V
Only one input can be programmed via AXIS NVR
manager, see Power Configuration, on page 13

Max input = + 30V

4

Input 2

5

Input 3

6

Input 4

7

Input 5

8

Input 6

9

Input 7

10

Input 8

11

5V DC
Power

Can be used to power auxiliary equipment.
Note:
This pin can only be used as power out.

Max load = 250mA

12

GND

Ground

LED Color

Indication

Network

Amber

Link established.

Green
Unlit

Steady for connection to 100 Mbit/s network
For connection to 1Gbit/s network

Power

Green

Power supplied - normal operation.

Green and
Amber

Battery powered

Unlit

Power off

PoE/Link

Green

Steady

Power is being supplied to the camera

Flash slowly

Short circuit

2 flash sequence

Error in PoE connection.

5 flash sequence

Connected units exceed the max load.

6 flash sequence

Connected units in the left or right group
exceed the max load.

Amber

Link established

Advertising