B. maintening the d060 hf-ns air valve – A.R.I. D-060HFNS EN User Manual

Page 2

Advertising
background image



B. Maintening the D060 HF-NS Air valve

.

Maintening the Automatic air valve

.

1

.

C


C.1.1. Shutoff the isolating valve below the air valve

.

C.1.2. Unscrew the body (1)of the Automatic air valve

(No.22

drawing no. 5292-00-02

) from the Base (make sure

that the base will not rotate!).

C.1.3. Remove the Clamping Stem (3)and the float (4)from

the automatiic component and wash the inside

of the body, the Clamping Stem, the float, and

the Rolling Seal (2),with clean water.

C.1.4.

Check to make sure that the Rolling Seal is unharmed

(not torn or cracked) and is located precisely in the

middle of its groove in the float.

C.1.5. Reassemble the air valve in the opposite order:

First insert half the lengh of the roaling seal tail

into the track (grrove) in the body, then push

the rest of the way to the end of the groove ,

using the clamp.Make sure that the

roalling seal is set and hold inits place.









A.R.I FLOW CONTROL ACCESSORIES LTD