D. Troubleshooting

PROBLEM CAUSE

SOLUTION

Leak From
the Small
Orifice

a. Dirt particles

stuck in the

orifice

a. Shut the isolating valve, wait a minute, and

open it again, very fast. If leaking continues,
go to b.

b. Rolling Seal

torn

b. Shut the isolating valve, Unscrew the cover

bolts of the automatic air valve, slowly, to
release accumulated pressure. Remove the
plastic cover with a screwdriver and clean
the orifice with flowing water and with a
thin copper wire. Wash the inside of the
body, the float, and the Rolling), with clean
water

c. Check to make sure the Rolling Seal is

unharmed (not torn or cracked). Replace the
Rolling Seal if needed.

Leak From
the Large
Orifice

Dirt particles
stuck on the
orifice seal,

a. Shut the isolating valve, wait a
minute, and open it again, very fast.
If leaking continues, go to b.

on the orifice seat,

b. Shut the isolating valve, unscrew the

or on the float.

air valve cover bolts, remove the cover, and
remove float. Check if the seal, the seat, or
the float are dirty, and clean them.