Troubleshooting:

Problem Possible

causes

Solutions.

No flow in the line

1. Shut off valves have not

been opened after
installation.

2. The product is installed

the wrong way round
(against the flow
direction).


3. Mains pressure is less

than 1 bar.

1. Check shut off valves.


2. Check direction of the

product, and if necessary
invert it in accordance
with the flow direction.

3. The UFR requires a

minimum mains pressure
of 1 bar to work normally.

There is a leak in the house
but the UFR is not working.

1. There is a lot of air in the

system following the
installation.


2. The leak in the house is

more than 30 liters per
hour (cumulative).


3. Sealant has entered the

sealing area of the UFR.

1. Purge air from the

system by opening the
taps in the house and
check again.

2. At more than 30 liters per

hour, the UFR stops
working, so there is no
problem.

3. Remove the UFR from

the line and clean out the
sealant.

Leak between the two parts
of the UFR

The UFR has opened up and
the O-ring no longer seals.

Tighten the two parts of the
UFR, open the water
pressure again, and check
for leaks.