Wm100-200-300-english, User instruction manual (ver. 5/07), Max. / avg. / wind speed – WeatherHawk WM-300 WindMate w/Wind Direction & Humidity User Manual

Page 2: Compass calibration (wm 200, 300), Getting started, Digital wind direction (wm 200, 300), Using the wind meter functions, Sequence for wm 100, Average wind speed (wm 100 only), Setting the comfort index™ (wm 300)

Advertising
background image

Mode

Keys

Mode/ On/ Off

ST / EL

(WM 100)

SET/ EL

(WM 200 & 300)

Units

W

M

100

W

M

200

W

M

300

Wind speed

Change mode

(Hold to turn power ON/ OFF)

---------------

Change Units

Max. Wind

speed

Change mode

(Hold to turn power ON/ OFF)

---------------

Change Units

Avg. Wind

speed

Change mode

(Hold to turn power ON/ OFF)

Start calculation (WM100)

Change Units

Compass

Change mode

(Hold to turn power ON/ OFF)

Hold to enter Compass

Calibration

Hold to mark

direction

Crosswind

Exit to compass

Hold to enter Compass

Calibration

Headwind

Headwind

Exit to compass

Hold to enter Compass

Calibration

Crosswind

Compass

Calibration

---------------

Exit to compass

---------------

Temperature

Change mode

(Hold to turn power ON/ OFF)

---------------

Change Units

Wind Chill

Change mode

(Hold to turn power ON/ OFF)

---------------

Change Units

Humidity

Change mode

(Hold to turn power ON/ OFF)

---------------

---------------

Wet Bulb

Change mode

(Hold to turn power ON/ OFF)

----

Change Units

Dew Point

Change mode

(Hold to turn power ON/ OFF)

---------------

Change Units

Comfort Index

Change mode

(Hold to turn power ON/ OFF)

Hold to enter Solar Factor

Setting

Change Units

Solar Factor

Setting

---------------

Exit to Comfort Index

Advance adjust

Delta T

Change mode

(Hold to turn power ON/ OFF)

---------------

Change Units

WindMate

®

100, 200, 300

User Instruction Manual

(Ver. 5/07)



























Max. / Avg. / Wind Speed

MPH---->KMPH---->MPS---->FPM---->BF---->KNT

Temp. / Wind Chill/ Wet Bulb/ Dew Point/ Comfort Index/
Delta T

0

F---->

0

C


Compass Calibration (WM 200, 300)

If necessary, to correct for the presence of

ferrous metals, the compass can be calibrated.

Go to compass mode press and hold SET/EL

key till display shows “COMPASS CAL”

(blinking). Turn the unit in a vertical position as

shown. Turn the unit around twice, 15 sec per

turn, as shown. After completing the 2 turns

press SET/EL key to confirm calibration. If the

display shows “END” the calibration is

successful. If the display shows “ERR” redo the

calibration process.


Getting Started

Open your WindMate

®

to 180

o

as shown. If using

a tripod, open your WindMate

®

to a 90

o

angle as

shown above to access the tripod fitting.

To turn the unit on or off, press and hold Mode

key for about 3 sec. You can turn off the unit at

any mode. If the unit is idle for 5 minutes, it will

auto shut down to preserve battery life.

When taking wind measurements by hand, make sure to

keep the WindMate

®

at arm’s length from the body with the

display facing towards you so the wind will enter the wind

impeller through the rear. Use the wind vane to orient the

wind meter so you are on the wind’s axis. This will give you

the most accurate measurement.

CAUTION: The WindMate

®

is very accurate at low and

mid-range air speeds. Consistent use at very high speeds,

such as from a fast-moving car, will damage the impeller’s

bearing and reduce its accuracy. See below for impeller

replacement.






Digital Wind Direction (WM 200, 300)

Point the WindMate

®

directly into the wind and select

Compass mode. The edge of the wind vane will point

directly towards you. Wind direction is displayed digitally

and in compass points.

The compass feature can also compute the cross and

head/tail wind. Point the meter in the direction of travel or

target and get a steady compass reading. Press and hold

Units key until MARK stops blinking. Release Units key

and point the meter into the wind until you have a steady

compass reading. Press and hold Units key until MARK

stops blinking. The meter will display cross wind and to view

head wind press the Units Key. The computed cross and

head/tail wind may indicate a minus (–) sign. The minus (–)

sign will indicate the wind is coming from the back, while no

sign will indicate that the wind is coming from the front. To

exit, press Mode.


Using the Wind Meter Functions

When the unit is turned on for the first time, the default
mode is wind speed. Going to other modes or features is
simply done by pressing the Mode button.

Pressing Units Key at any mode, except Compass and
Humidity (WM 200, 300 only), changes the unit to your
preferred measurement unit. Units of measurement
sequence is shown below for each model.

Sequence for WM 100
• Wind speed – displays real time wind speed

• Max. wind speed – displays the max. wind speed

• Avg. wind speed – 5 sec

• Avg. wind speed – 10 sec

• Avg. wind speed – 13 sec

Max. / Avg. / Wind Speed
MPH---->KMPH---->MPS---->FPM---->BF---->KNT

Average Wind Speed (WM 100 only)

The WM 100 is equipped with 3 average wind speed options
5, 10 and 13 sec. Select the desired time duration in which
the unit will calculate the average wind speed. Press the
ST/EL key to start the count down. When the count down
reaches zero the average wind speed will be shown. To
take another average wind speed press ST/EL key.




Setting the Comfort Index™ (WM 300)

Accuweather.com® Comfort Index™ is the effect of temp,
relative humidity, wind speed & sun intensity on the human
body. You can adjust the formula based on sun intensity.
The solar factor has a range of 0 to 3.0 with a default setting
of 1.5 (medium sun intensity). Example: Full sun = 3.0;
Heavy clouds = 0. To change, press and hold SET/EL key.
Press Units key to adjust the current value of the solar
factor and press SET/EL to confirm and exit the setting
mode.

Replacing the Battery (All models)

The unit uses a CR2032 Lithium battery. Turn the unit to the
back. Use a coin to turn battery cover as indicated by the
arrow. Insert the battery with the printed side facing you and
close the battery door.

Changing the Wind Impeller (All models)

WindMate

®

impellers can be replaced. Contact your dealer,

distributor or WeatherHawk for parts and instructions.
Your instrument has a 2-year warranty. Please save your
invoice for verification and contact WeatherHawk for
questions or service:

435-750-1840, M-F 8:00 to 5:00, USA Mountain Standard Time
www.weatherhawk.com


Sequence for WM 200

• Wind speed – displays real time wind speed

• Max. wind speed – displays max. wind speed

• Avg. wind speed – displays 10-sec average

• Compass

• Temperature

• WindChill


Max. / Avg. / Wind Speed


MPH---->KMPH---->MPS---->FPM---->BF---->KNT


Temp. / Wind Chill

0

F---->

0

C


Sequence for WM 300
• Wind speed – displays real time wind speed

• Max. wind speed – displays the max. wind speed

• Avg. wind speed – displays 10-sec average

• Compass

• Temperature

• WindChill

• Humidity (Sensor is self-calibrating)

• Wet Bulb

• Dewpoint

• Comfort Index

• Delta Temperature




Key Function Matrix























































Wind Impeller

Wind Vane

Units

ST/ EL (WM 100)

SET/ EL (WM 200, 300)

Mode/ On/ Off
Tripod Fitting

1

2

3

4

5

6

7

8

9