LEAkAGE ChECkPoInts

INSTrUCTIoNS: USE ThIS ILLUSTrATIoN AS A GUIdE whEN ChECkING For SoUrCES oF wATEr LEAkAGE.

All water which appears at the heater bottom or on the

surrounding floor may be caused by condensation, loose

connections or relief valve operation and leakage. Do not

replace the heater until a full inspection of all potential leak

points is made and corrective steps taken to stop the leak.

Leakage from other appliances, water lines, or ground seepage

should also be suspected until proved otherwise.

Where possible, remove or lift top cover to

examine threads of fittings installed into tank

for evidence of leakage. Correct fitting leaks

as necessary.

Relief valve operation and leakage may be

due to water expansion during heating cycle

or foreign material on seat of valve. If the valve

is not piped to an open drain, the released

water could be mistaken for a leaking heater.

To check where threaded portion enters tank,

insert Q-Tip® or similar absorbent material

between jacket opening and valve to swab

spud area. Remove valve* if leak is indicated

and repair with pipe joint compound.

Water on the side of the tank may be

condensation due to the panel or insulation

not being in place.

Water leaks at the elements may be due to:

1. Defective elements which leak at terminals

or through flange. Replace element*.

2. Loose element/gasket leak:

Tighten element with element wrench.

If leak continues, remove element* and

discard gasket. Clean gasket seating

areas and reinstall element with new

gasket.

Condensation and dripping may appear on

pipes when inlet water temperature is low.

Pipe fitting may be leaking.

Drain valve leakage could be from the valve itself. Either

correct the problem or replace the valve*. To check for

leakage where threaded portion enters tank, insert Q-tip

or similar absorbent material between jacket opening

and valve to swab spud area. Remove valve* if leak is

indicated and repair with pipe joint compound.

* Contact a Qualified Service Agency as it is necessary to

shut off electricity and drain tank to perform procedure.