Legend – State SBL100 76 NE User Manual

Page 30

Advertising
background image

30

NOTES:

1.

Preferred piping diagram

.

2.

The temperature and pressure relief valve setting shall not exceed pressure rating of any component in the system

.

3.

Service valves are shown for servicing unit. However

, local codes shall govern their usage.

4.

The

Ta

nk

Te

mperature Control should be wired to and control the pump between the water heater(s) and the storage tank(s).

5.

The water heater

’s

operating thermostat should be set 5 degrees F higher than the

Tank

Te

m

perature Control

.

SINGLE FL

UE

- (1 UNIT) WITH MIXING

VA

LVE

TWO

TEMPERA

TURE

LEGEND

TEMPERA

TURE & PRESSURE

RELIEF

VA

LV

E

PRESSURE RELIEF

VA

LV

E

CIRCUL

AT

ING PUM

P

TA

NK

TEMPER

AT

URE CONTRO

L

DRAIN

FULL

PO

RT

BALL

VA

LV

E

TEMPERA

TURE GAGE

WA

TER FLOW SWITCH

CHECK

VA

LV

E

WA

RNING:

THIS DR

AW

ING SHOWS SUGGESTE

D

PIPING CONFIGURA

TION

AND OTHER DEVICES

;

CHECK WITH LOCA

L

CODES

AND ORDINANCES

FOR

ADDITIONAL

REQUIREMENTS

.

HOT WATE

R

RETUR

N

MINIMUM 10

´´ to

12

´´

HOT WATER OUTLET

TEMPERED

WATER RETUR

N

TEMPERED

WATE

R

OUTLET

COLD WATE

R

SUPPLY

LINE

TEMPERATURE

CONTROL

COLD

HO

T

EXPANSION

TANK

PIPE T&P TO OPEN DRAI

N

Advertising