Posey Peek-A-Boo® Mitts User Manual

Application instructions, Rx only peek-a-boo mitt

Advertising
background image

Posey Company • 5635 Peck Road, Arcadia, CA 91006-0020 USA • www.posey.com

Phone: 1.800.447.6739 or 1.626.443.3143 • Fax: 1.800.767.3933 or 1.626.443.5014



MDSS GmbH

Schiffgraben 41

D-30175 Hannover, Germany

EC REP

ApplicAtion

instructions

BED SAFETY
• ALWAYS use Hospital Bed Safety

Workgroup (HBSW) (http://www.

fda.gov/cdrh/beds/modguide.html)

compliant side rails in the UP

position and fill ALL gaps to reduce the risk of

entrapment.

• Use side rail covers and gap protectors to help prevent

the patient’s body from going under, around, through

or between the side rails. A failure to do so may result

in serious injury or death if a patient becomes

suspended or entrapped. Posey offers a full range of

side rail pads and/or gap protectors to cover gaps.

ADDITIONAL OR DIFFERENT BODY OR LIMB

RESTRAINTS MAY BE NEEDED (See Posey Catalog):
• To reduce the risk of the patient getting access to the

line/wound/tube site;

• To prevent the patient from flailing or bucking up and

down and causing self-injury.

MONITOR PER FACILITY POLICY. Check to ensure that:
• Mitts are properly secured. If applied too tightly,

circulation will be restricted; if applied too loosely, the

patient may be able to slip his or her limb from the

device;

• Mitts are intact, not torn or damaged, and hook and

loop closes securely. DO NOT allow patients to ingest

mitt material;

• The patient cannot use his or her teeth or otherwise

remove the device and inflict self-injury;

• Monitor closely when the patient is out of bed.

Patients who ambulate while wearing this device may

be at risk of injury from a fall.

ApplicAtion instructions (Repeat steps 1-3 for each mitt):
NoTE: Product is not designed for use with a connecting strap

(See Posey Catalog for other options).

1. Insert the patient’s hand into the mitt,

palm down. When the inspection flap is

open, the back of the hand should be

visible (fig. 1).

2. Wrap the wrist strap around the

smallest part of the patient’s wrist,

through the plastic ring, and secure

with the hook and loop fastener.

3. Slide ONE finger (flat) between the device and the inside of

the patient’s wrist to ensure proper fit. The strap must be

snug, but not compromise circulation.

To view hand/fingers:

1. Reach under the inspection flap, detach the hook and loop

fastener, and pull back the flap to expose the hand.

2. To close the inspection flap, tuck into the end of the mitt

and press the hook and loop closure together firmly.

Applicable Products:

REF

2811

DEscription oF proDuct: A double padded mitt to hinder picking and tube pulling.

rx onlY

pEEK-A-Boo Mitt

© 2009 Posey Company. All rights reserved.

I9269 060609

2811

posEY pEEK-A-Boo Mitt

REF

2811

Peek-A-Boo Mitt

inDicAtions For usE:
• Patients assessed to be at risk of disrupting life-saving treatments (e.g., chronic

tube pulling).

• Patients assessed to be at risk of line pulling, which may prevent monitoring of vital

signs.

• Patients whose picking, pulling, scratching, or peeling exacerbates a skin condition,

causes self-injury, or compromises wound site integrity.

NEVER use mitts on a patient:

If an IV or wound site could be compromised by the device.

With a dislocation or fracture on the affected limb.

See the Posey Catalog for other options for such a patient.

contrAinDicAtions:

Do NoT use on a patient who is or becomes highly aggressive, combative,

agitated, or suicidal.

ADVErsE rEActions
• Severe emotional, psychological, or physical problems may occur: if the applied

device is uncomfortable; or if it severely limits movement. If symptoms of these

problems ever appear for any reason, get help from a qualified medical authority

and find a less restrictive, product or intervention.

Fig. 1

ADDitionAl sAFEtY AnD lAunDEring