ApplicAtion instructions

1. Open the Soft Splint by releasing the hook-and-loop adjustment

straps.

2. Orient the Splint so that the plastic buckles are positioned towards

the patient.

3. Adjust the Splint to the desired position on the limb. The Splint

should be centered over the elbow with the opening towards the

inside of the arm. For leg application, the Splint should be centered

over the knee with the opening towards the front of the leg.

4. Secure the Splint by threading the hook-and-look strap through the

plastic buckle and securing back onto itself. Leave enough room to

easily insert two fingers between the device and the patient’s limb

to maintain adequate circulation.

OPTIONAL
5. To reduce the Splint size (i.e. for a limb that is in between sizes),

fold the outside panel with hook-and-loop towards the inner lining,

minimizing the Splint width. Continue by following steps 2-4 as

described above.

• An external hand, wrist, elbow and knee splint.
• 100% cotton lining with a vinyl mesh outer cover.
• Polystyrene bead filling conforms to the limb and helps equalize

pressure with comfort and stability.

• Zippered opening allows adjustable fill to suit patient comfort.
• Effective as Splints during IV therapy and on extremities for the

treatment of compound fractures requiring frequent treatment.

• Available in pediatric through adult leg sizes.
• One per package.

lAundering instructions:

Monitor skin condition frequently.

DO nOT overtighten or impair circulation!

M6140 072409

NEVER alter or repair this product. ALWAYS Inspect before each use: Check for broken stitches or parts; torn, cut or frayed material; or

hook and loop fasteners that do not hold securely. DO nOT use soiled or damaged products. Doing so may result in serious injury or death.

Dispose of damaged products per facility policy for BIOHAZARDOUS material.

storAge And HAndling

This device is designed for use in normal indoor environments.

This device may be stored in ambient warehouse temperatures

at normal humidity levels. Avoid excess moisture or high

humidity that may damage product materials.

DO nOT allow patients to ingest product material.

POSEY

CIRCUMFERENCE

OLD

PRODUCT# SIZE

MEASUREMENTS

NUMBER

REF

8170P

Pediatric

Fits up to 6½” (16½ cm)

3SS1-P

REF

8170S

Small

Fits 7” –9” (18-23 cm)

3SS2-S

REF

8170M

Medium

Fits 10” - 12” (25-30 cm)

3SS3-M

REF

8170L

Large

Fits 13” – 15” (33-38 cm) 3SS4-L

REF

8170XL

X-Large

Fits 16” – 18” (41-46 cm) 3SS5-XL

REF

8170XXL XX-Large Fits 19” - 21” (48-53 cm)

3SS6-XXL

Advertising