Posey Pelvic Soft Belt User Manual

Application instructions, Rx only soft belt

Advertising
background image

Posey Company • 5635 Peck Road, Arcadia, CA 91006-0020 USA • www.posey.com

Phone: 1.800.447.6739 or 1.626.443.3143 • Fax: 1.800.767.3933 or 1.626.443.5014



MDSS GmbH

Schiffgraben 41

D-30175 Hannover, Germany

EC REP

ApplicAtion

instructions

• Monitor per facility policy to ensure that the patient

cannot slide down, or fall off the chair seat and become

suspended (fig. 4).

• There is a risk of chest compression or suffocation, if the

patient’s body weight is suspended off the chair seat. Use

extreme caution with chair cushions. If a cushion dislodges,

straps may loosen and allow the patient to slide off the

seat (fig. 4).

• STOP USE AT ONCE: if the patient has a tendency to slide

forward or down in the device; or is able to self-release.

• Monitor skin conditions in the groin area frequently. If the

patient slides down or forward, pelvic straps may damage

the skin.

1. Lay the device on the chair with the narrow side to the back

of the chair.

2. Bring the ends of the connecting straps on

the narrow end, down behind the chair, and

secure out of the patient’s reach (fig. 1).

3. Position the patient as far back in the

seat as possible, with the buttocks

against the back of the chair.

4. Bring the wide part of the pelvic holder up

between the patient’s legs.

5. Bring the ends of the connecting straps

on the wide end, down between the seat

and wheelchair sides at a 45-degree angle

(fig. 2).

6. Criss-cross the straps and use quick-

release ties to attach the straps to the

opposite side kick spurs, out of the

patient’s reach (fig. 3).

7. If the chair has an adjustable seat, secure

straps to a movable part of the chair

frame, out of the patient’s reach.

8. Check that the straps are secure and will not change position,

loosen, or tighten if the patient pulls on them, or if the chair

is tilted or adjusted.

Before use, check device for damage. Discard if you

have any questions about patient safety.

ApplicAtion instructions:

inDicAtions For usE:

contrAinDicAtions:

ADVErsE rEActions

• Severe emotional, psychological, or physical problems may occur: if the applied device is

uncomfortable; or if it severely limits movement. If symptoms of these problems ever appear

for any reason, get help from a qualified medical authority and find a less restrictive, product or

intervention.

• Patients who have a tendency to slide down in a chair.

• Patients needing a positioning device for added safety while in a chair.

• Patients assessed to be at risk of injury from a fall.

DO NOT use on patients with: ostomy, colostomy, or G-tubes; hernias, severe Cardio

Obstructive Pulmonary Disease (COPD); or with post-surgery tubes, incisions, catheters, or

monitoring lines. These could be disrupted by a restraint.

DO NOT use on a patient who is or becomes highly aggressive, combative, agitated, or

suicidal.

Applicable Products:

REF

4125c

DEscription oF proDuct: A pelvic holder to prevent sliding. For chair use only.

rx onlY

soFt BElt

© 2009 Posey Company. All rights reserved.

I92100 040609

4125c

posEY soFt BElt

REF

4125C Chair use only; 4½”W x

16½” (11 cm x 42 cm) belt

pad w/6 foot (2 m) straps

FiG. 4

ADDitionAl sAFEtY AnD lAunDErinG

instructions on othEr siDE

FiG. 1

FiG. 2

45˚

FiG. 4

Heed these warnings to reduce the risk of serious injury or

death:

ApplicAtion instructions: (plAstic incontinEncE

shiElD):
1.
Insert the pelvic straps through the shield starting at the

widest part and pull the shield up until it rests on the foam

pelvic piece.

FiG. 3

Make sure patient wears proper undergarments

to protect skin.

Advertising