Posey Synthetic Leather Cuffs/Leather Locking Cuffs User Manual

Application instructions, Rx only non-locking cuffs

Advertising
background image

Posey Company • 5635 Peck Road, Arcadia, CA 91006-0020 USA • www.posey.com

Phone: 1.800.447.6739 or 1.626.443.3143 • Fax: 1.800.767.3933 or 1.626.443.5014



MDSS GmbH

Schiffgraben 41

D-30175 Hannover, Germany

EC REP

ApplicAtion

instructions

ADVErsE rEActions

• Severe emotional, psychological, or physical problems may occur: if the applied device is uncomfortable; or

if it severely limits movement. If the patient is likely to cause injury to him/herself or others, get help from a

qualified medical authority to find an alternate intervention or method of restraint.

inDicAtions For usE:

• Patients assessed as being in extreme danger of injury to themselves or to

others.

• Patients assessed to be at risk of disrupting life-saving treatments (e.g., chronic

tube pulling).

• Patients assessed to be at risk of line pulling, which may prevent monitoring of

vital signs.

• Patients whose picking, pulling, scratching, or peeling exacerbates a skin

condition, causes self-injury, or compromises wound site integrity.

contrAinDicAtions:

NEVER use on a patient:

With a dislocation or fracture on the restrained limb; or

If an IV or wound site could be compromised by the device.

See the Posey Catalog for other options for such a patient.

DO NOT use this device on a patient who is or becomes: suicidal; highly aggressive or combative; self-

destructive; or deemed to be an immediate risk to others, UNLESS the patient is under constant supervision.

Applicable Products:

REF

2202, 2203

DEscription oF proDuct: Wrist/ankle restraints for use with violent patients and/or patients who are potentially dangerous to themselves or others.

rx onlY

non-locking cuFFs

© 2009 Posey Company. All rights reserved.

I9239 062109

2202

posEY liMB HolDErs

REF

2202 Leather wrist/ankle cuffs -

Suede lined

REF

2203 Synthetic leather wrist/

ankle cuffs

(Connecting Straps sold separately)

2203

ADDITIONAL OR DIFFERENT BODY OR LIMB RESTRAINTS MAY BE

NEEDED (See Posey Catalog):

• If the patient pulls violently against the bed straps;

• To reduce the risk of the patient getting access to the line/wound/

tube site;

• To prevent the patient from flailing or bucking up and down and

causing self-injury.

• Check the patient regularly to ensure that:

Circulation is not impaired. Serious injury may occur if the cuffs

restrict circulation.

Cuffs are secure. Death or serious injury to the patient or others

may occur if the patient can remove the cuffs.

MONITORING

• Posey recommends constant direct supervision for patients deemed to be

at risk of injury to themselves or others. For times when direct supervision

is not possible, monitor by line of sight or by a video/audio device.

• NEVER allow a patient to have access to any tool, utensil, or object

that might be used to unlock or damage cuffs.

• Be aware that a sudden mood swing may cause agitated or

aggressive behavior. Contact the medical team AT ONCE if this

occurs. No level of monitoring may avoid the risk of serious injury to

highly agitated or aggressive patients.

BED SAFETY

• ALWAYS use Hospital Bed Safety Workgroup

(HBSW) (http://www.fda.gov/cdrh/beds/

modguide.html) compliant side rails in the UP

position and fill ALL gaps to reduce the risk of

entrapment.

• Use side rail covers and gap protectors to help prevent the patient’s

body from going under, around, through or between the side rails. A

failure to do so may result in serious injury or death if a patient

becomes suspended or entrapped. Posey offers a full range of side

rail pads and/or

gap protectors to

cover gaps.

ApplicAtion instructions:

• Before each use, check cuffs and straps for cracks, tears, and/or

excessive wear or stretch; cracked or broken buckles or locks; and/or

that hook and loop adheres securely, as these may allow patient to

remove cuff. Discard if device is damaged.

• If you have any questions about patient safety, ask the appropriate

medical authority for alternatives.

Follow these steps to apply device (repeat steps 1-3 on the other limb):

1. Wrap the cuff around the patient’s limb.

2. Bring the U-bar through the closest vertical slot and then pass the

tongue through the U-bar.

3. Check for proper fit by inserting one finger between the cuffs and the

patient’s wrist or ankles. The cuffs must be snug enough to prevent

escape, but not interfere with circulation.

ApplicAtion instructions: (Connecting Straps) (sold

separately)

1. Loop the connecting strap (sold separately) through the U-bar on the

cuff.

2. Wrap the strap around the juncture of a movable part of the bed frame,

out of the patient’s reach. Ensure that the strap is wrapped around the

frame at least once before passing the end of the strap through the

buckle or lock.

Use extreme caution when using any type of padding with the limb

holder. If the patient pulls violently, the padding may compress and

allow the patient to remove the cuff and cause injury to himself/herself

or others.

MONITOR PER FACILITY POLICY. Check to ensure that:

• Straps cannot slide in any direction, tighten or loosen if the patient

pulls on them, or if the bed is adjusted;

• Cuffs are attached in a way that the patient is not able to use his or

her teeth or otherwise remove the device;

• Cuffs are intact, and not torn or damaged. DO NOT allow patients to

ingest product material.

ADDitionAl sAFEtY AnD lAunDEring

instructions on otHEr siDE