Set the hdsl operating mode and transmission rate, Hdsl o, Perating – ADC Campus RS Destop Unit User Manual

Page 21: Ransmission

Advertising
background image

Installing and Configuring the Line Unit

Campus-RS Line Unit User Manual

May 29, 2002

13

S

ET

THE

HDSL O

PERATING

M

ODE

AND

T

RANSMISSION

R

ATE

This section provides generic instruction for setting the HDSL Operating
Mode and transmission rate. The actual steps depend on the interface card
mated with the Line Unit. Refer to the manual for the interface card for a
description of configuration options and complete configuration instructions.

The steps in this section use the menu buttons and LCD on the Campus-Star’s
Campus Management Unit (CMU). To set the HDSL Transmission Rate:

1

Use the Slot selection buttons to select the slot in which you installed the
Line Unit. The LCD displays:

MARGIN (LOC/RMT)

1:XX/XX 2:XX/XX

2

Press Escape four times to go to the top level menu.

3

Press Next until

HDSL LINK CONFIG & STATUS

displays, then press

Enter.

4

Continue with one of the following sections, depending on whether you
are using Standard Mode or Extended Mode.

CMU-710 MANAGEMENT UNIT

SLOT

RESET

POWER

RS-232

ALARMS

MAJOR

MINOR

ACO

Menu buttons

Console port

Reset button

LCD display

Slot selection control pad

System alarm LEDs

NEXT

ENTER

ESC

1061.book Page 13 Wednesday, May 29, 2002 8:59 AM