RocketRAID BIOS Utility

5 - Settings

To access the Settings menu, highlight the Settings command from the toolbar, and

press Enter.

Generally, single disks are designated to act as spares (disks that are not configured

into RAID arrays).

However, in some instances, disks that are members of RAID arrays may also be

designated to act as a spare. If the disks in question are part of a RAID array that did

not utilize the full available capacity at the time of creation, these disks may be used

as spares. For example: a RAID 0 array was created between two 200GB hard disks,

but only 200GB of space (out of a grand total of 400GB), was assigned to that array. In

this example, 200GB of disk space remains unallocated. This unallocated space would

allow these disks to be set as spares for a separate redundant array that falls into the

same capacity range (200GB).

Select Boot Device – select which disk or array will act as the boot disk, if the

motherboard BIOS instructs the card to act as the boot device.

Staggered Drive Spinup – This option is disabled by default. Enabling this setting

will instruct the card to power up the hard disks, sequentially (one disk approximately

every 2 seconds). Not all disk support this setting – consult the disk documentation

for more information.