Ronbow 619623 User Manual

Led and metal medicine cabinet

Advertising
background image

Rev. Oct, 2013

ronbow.com

INStALLAtION GUIDe

INStALLAtION SHeet

ACCESSORIES

MODEL: 618523

619623

LED AnD MEtAL MEDICInE CABInEt

MATERIALS NEEDED:

PHILIP SCREWDRIVER
STUD LOCATOR
LEVELING TOOL

MATERIAL PROVIDED:

(4)WOOD SCREWS
(4)MOUNTING HARDWARE
(2)GLASS SHELVES
(8)MOUNTING HARDWARE FOR SHELVES

NOTE:

locate the wire at the top of the cabinet. The qualified license electrician has the option to plug into a wall outlet, or hard

wire the cabinet by cutting the plug.

Circuit Breaker

If your new medicine cabinet has a built-in led then follow the section below.

ALL wIRINg ShOuLD bE DONE by A quALIfIED LIcENSED ELEcTRIcIAN.

wARNINg:

To reduce the risk of electrical shock, shut off power before wiring the cabinet.

cAuTION:

Requires 120V 20AMP circuit.

cAuTION:

This product must be connected to a grounded, metal permanent wiring system or an equipment-grounding

conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lean on the product.

cAuTION:

A LED option cabinet must be wired to a 20AMP GFI (ground fault interrupter) circuit breaker when used in

bathrooms and all other locations required by the national electric code.

Wall Terminal

Black

Black

White

White

Ground

20AMP CFI