SPIRAL BEVEL GEARBOXES RANGE “POWERGEAR”





With mineral oil types, we recommend to make a first oil change after 500 operating hours and after
any 5000 operating hours in each case thereafter. When running the gearboxes with synthetic oil
types and on continuous duty near to the thermal load limit, we recommend to perform an oil change
after any 10, 000 operating hours and, if running them under usual conditions, after 15,000 operating
hours in each case.

Oil Volumes

(Dependant on gear ratio, rpm, shaft arrangement and installation position)

Construction size

P75/X75 P90/X90 P110/X110 P140/X140 P170/X170 P210/X210 P240/x240 P280/x280

Average oil volume

0.11

0.21 0.31 0.41 1.01 2.21 2.61 3.01

Max. Oil Volume

- - 0.351 0.61 1.21 2.51 3.51 5.01



Wear part kits including replacement and repair instructions can be obtained from our service
department.