Red Lion G3CN User Manual

General description, Safety summary, Contents of package

Advertising
background image

1

GENERAL DESCRIPTION

The G3 proprietary expansion slot provides a high speed, parallel architecture

that extends the functionality and flexibility of the G3 series HMI. This

approach allows the G3 series to evolve concurrently with the latest advances in

communications and standards, without sacrificing performance. This high

bandwidth channel has significantly greater throughput when compared to the

traditional (external) serial gateway approach.

The G3CN option card is easily installed by removing the rear cover of your

G3 operator interface, attaching the card using three screws and connecting a

single cable. Adding this card gives the operator interface a CANopen

communications port. It is built with digital isolation to protect the operator

interface from the CANopen bus and vice versa. It provides the ability to

communicate to any high speed CANopen device. The G3CN option board has

a termination resistor built-in, and is selectable through a jumper setting. A

connector housing is provided to function as a strain relief for the wires that

terminate into the five position connector. The connector is pluggable for easy

removal of the G3 operator interface from the CANopen bus, without disturbing

communications with other devices on the bus.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the

literature or on equipment must be observed to ensure personal safety and to

prevent damage to either the instrument or equipment connected to it. If

equipment is used in a manner not specified by the manufacturer, the protection

provided by the equipment may be impaired.

Do not use the controller to directly command motors, valves, or other

actuators not equipped with safeguards. To do so can be potentially harmful to

persons or equipment in the event of a fault to the controller.

CONTENTS OF PACKAGE

- G3CN Option Card with pluggable connector

- Cable already attached to G3CN option card

- Hardware pack consisting of three screws and a connector housing for the

pluggable connector

- This hardware bulletin

ORDERING INFORMATION

1

Use this part number to purchase Crimson on CD with a printed

manual, USB cable, and RS-232 cable. Otherwise, download from www.

redlion.net/g3.

MODEL G3CN - CANopen OPTION CARD FOR G3 OPERATOR

INTERFACE

TERMINALS

Bulletin No. G3CN-E
Drawing No. LP0587
Released 03/14

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

CAUTION: Risk of Danger.

Read complete instructions prior to

installation and operation of the unit.

Connector

(side 2)

mounting holes, 3 plcs.

MODEL NO.

DESCRIPTION

PART NUMBER

G3CN

G3CN0000

SFCRM2 Crimson 2.0

1

SFCRM200

CONFIGURED USING CRIMSON SOFTWARE (VERSION 2.0 OR

LATER)

DIGITALLY ISOLATED CANOPEN PORT CAPABLE OF

COMMUNICATING WITH ANY CANopen DEVICE

POWERED AND CONFIGURED FROM G3 OPERATOR

INTERFACE TERMINAL

BUILT-IN TERMINATION RESISTOR SELECTABLE THROUGH

JUMPER SETTING

INSTALLATION AND CONNECTION HARDWARE INCLUDED

WITH CARD

CANopen option card for G3 operator

interfaces with isolated high speed

communications ports

WARNING - EXPLOSION HAZARD - SUBSTITUTION OF ANY

COMPONENT MAY IMPAIR SUITABILITY FOR CLASS I,

DIVISION 2

THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS I,

DIVISION 2, GROUPS A, B, C, D, HAZARDOUS LOCATIONS,

OR NON-HAZARDOUS LOCATIONS ONLY

WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT

EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA

IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS.

Advertising