PAX2D

1/8 DIN Digital Input Panel Meter

Installation Guide

See the Red Lion website at www.redlion.net or the enclosed

USB thumbdrive for a complete user manual

SPECIFICATIONS

POWER:

AC Power: 40 to 250 VAC, 50/60 Hz, 20 VA

DC Power: 21.6 to 250 VDC, 8 W

Isolation: 2300 Vrms for 1 min. to all inputs and outputs.

INPUTS A and B:

DIP switch selectable to accept pulses from a variety of sources including

switch contacts, TTL outputs, magnetic pickups and all standard RLC

sensors.

LOGIC: Input trigger levels V

IL

= 1.5 V max.; V

IH

= 3.75 V min.

Current sinking: Internal 7.8 KΩ pull-up to +5 VDC, I

MAX

= 0.7 mA.

Current sourcing: Internal 3.9 KΩ pull-down, 7.3 mA max. @ 28 VDC,

V

MAX

= 30 VDC.

Filter: Damping capacitor provided for switch contact bounce. Limits

input frequency to 50 Hz and input pulse widths to 10 msec. minimum.

MAGNETIC PICKUP:

Sensitivity: 200 mV peak

Hysteresis: 100 mV

Input impedance: 3.9 KΩ @ 60 Hz; Must also have SRC switch ON. (Not

recommended with counting applications.)

Maximum input voltage: ±40 V peak, 28 Vrms

DUAL COUNT MODES:

When any dual count mode is used, then User Inputs 1 and/or 2 will accept

the second signal of each signal pair. The user inputs do not have the

Logic/Mag, HI/LO Freq, and Sink/Source input setup switches. The user

inputs are inherently a logic input with no low frequency filtering. Any

mechanical contacts used for these inputs in a dual count mode must be

debounced externally. The user input may only be selected for sink/source

by the User Jumper placement.

SENSOR POWER:

+18 VDC, ± 5% @ 60 mA max.; short circuit protected

USER INPUTS: Three programmable user inputs

Max. Continuous Input: 30 VDC

Isolation To Sensor Input Common: Not isolated.

PRESCALER OUTPUT:

NPN Open Collector: I

SNK

= 100 mA max. @ V

OL

= 1 VDC max. V

OH

= 30

VDC max. Duty cycle 25% min. and 50 % max.

ENVIRONMENTAL CONDITIONS:

Operating Temperature Range: 0 to 50 °C

Storage Temperature Range: -40 to 60 °C

Vibration to IEC 68-2-6: Operational 5-150 Hz, 2 g

Shock to IEC 68-2-27: Operational 25 g (10 g relay)

Operating and Storage Humidity: 0 to 85% max. RH non-condensing

Altitude: Up to 2000 meters

CERTIFICATIONS AND COMPLIANCES:

CE Approved

EN 61326-1 Immunity to Industrial Locations

Emission CISPR 11 Class A

IEC/EN 61010-1

RoHS Compliant

UL Listed: File #E179259

Type 4X Indoor Enclosure rating (Face only)

IP65 Enclosure rating (Face only)

IP20 Enclosure rating (Rear of unit)

CONNECTIONS: High compression cage-clamp terminal block

Wire Strip Length: 0.3" (7.5 mm)

Wire Gauge Capacity: One 14 AWG (2.55 mm) solid,

two 18 AWG (1.02 mm) or four 20 AWG (0.61 mm)

CONSTRUCTION: This unit is rated NEMA 4X/IP65 for indoor use only.

IP20 Touch safe. Installation Category II, Pollution Degree 2. One piece

bezel/ case. Flame resistant. Synthetic rubber keypad. Panel gasket and

mounting clip included.

WEIGHT: 8 oz. (226.8 g)

Drawing No. LP0901A
Effective 04/13

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

C

US LISTED

UL

R

3RSD

PROCESS CONTROL EQUIPMENT

3.80 (96.52)

(49.53)

(2.54)

(44.45)

3.60 (91.44)

4.14 (105)

1.95

0.10

1.75

1

3

2

4

DIMENSIONS In inches (mm)

Note: Recommended minimum clearance (behind the panel) for mounting clip

installation is 2.1" (53.4) H x 5.5" (140) W.

Advertising