Red Lion CUB5I User Manual

General description, Safety summary, Dimensions in inches (mm)

Advertising
background image

1

FOUR SELECTABLE D.C. RANGES

200

A, 2 mA, 20 mA, 200 mA

MINIMUM AND MAXIMUM DISPLAY CAPTURE

LCD, REFLECTIVE OR RED/GREEN LED BACKLIGHTING

0.48" (12.2 mm) HIGH DIGITS

OPTIONAL SETPOINT OUTPUT CARD

OPTIONAL SERIAL COMMUNICATIONS CARD (RS232 or RS485)

OPTIONAL USB PROGRAMMING CARD

OPERATES FROM 9 TO 28 VDC POWER SOURCE

FRONT PANEL OR CRIMSON PROGRAMMABLE

DISPLAY COLOR CHANGE CAPABILITY AT SETPOINT OUTPUT

NEMA 4X/IP65 SEALED FRONT BEZEL

MODEL CUB5I - MINIATURE ELECTRONIC 5-DIGIT DC CURRENT METER

GENERAL DESCRIPTION

The CUB5 provides the user the ultimate in flexibility, from its complete user

programming to the optional setpoint control and communication capability.
The CUB5I accepts a DC Current input signal and provides a display in the
desired unit of measure. The meter also features minimum and maximum
display capture, display offset, units indicator, and programmable user input.
The display can be toggled either manually or automatically between the
selected displays.

The CUB5 display has 0.48" (12.2 mm) high digits. The LCD is available in

two versions, reflective and red/green backlight. The backlight version is user
selectable for the desired color and also has variable display intensity.

The capability of the CUB5 can be easily expanded with the addition of

option cards. Setpoint capability is field installable with the addition of the
setpoint output cards. Serial communications capability for RS232 or RS485 is
added with a serial option card.

The CUB5 can be powered from an optional Red Lion Micro-Line/Sensor

Power Supply (MLPS), which attaches directly to the back of a CUB5. The
MLPS is powered from 85 to 250 VAC and provides up to 400 mA to drive the
unit and sensors.

CURRENT

The CUB5I is the DC Current meter. It features 4 current input ranges, that

are selected by the user via a programming jumper and software input range
selection. The ranges consist of following: 200

A, 2 mA, 20 mA, or 200 mA.

Users should select the appropriate current range that covers their maximum
signal input.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in this

literature or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.

Do not use this meter to directly command motors, valves, or other actuators

not equipped with safeguards. To do so can be potentially harmful to persons or
equipment in the event of a fault to the meter.

Bulletin No. CUB5I-K
Drawing No. LP0658
Released 02/13

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

CAUTION: Risk of Danger.

Read complete instructions prior to

installationand operation of the unit.

CAUTION:

Risk of electric shock.

DIMENSIONS In inches (mm)

.13 (3.3)

(43.4)

1.71

2.95 (74.9)

SEL

.15 (3.8)

1.54 (39.1)

RST

(68 )

+.025

-.000
+8

-0

1.29 (32.8)

2.68

-.000

1.30

(33 )

-0

+6

+.024

Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.15" (54.6) H x 3.00" (76.2) W.

CC

US LISTED

US LISTED

UL

R

51EB

IND. CONT. EQ.

Advertising