Red Lion PAXT User Manual

Model pax – 1/8 din analog input panel meters, Cus listed, General description

Advertising
background image

1

3.80

1.95

.10

4.10

(2.5)

(96.5)

(49.5)

(104.1)

1.75

(44.5)

RST

DSP

PAR F1

F2

X

MA

O

M

T T

N

I

1

SP

3

S

2

SP

P

P4

S

8.8.8.8.8

V

(44.5)

1.75

1 2 3 4 5 6 7 8 9 10 11

12
13
14
15

16
17
18
19

20
21
22
23
24
25

3.60 (91.4)

PROCESS, VOLTAGE, CURRENT, TEMPERATURE, AND STRAIN

GAGE INPUTS

5-DIGIT 0.56" RED SUNLIGHT READABLE DISPLAY

VARIABLE INTENSITY DISPLAY

16 POINT SCALING FOR NON-LINEAR PROCESSES

PROGRAMMABLE FUNCTION KEYS/USER INPUTS

9 DIGIT TOTALIZER (INTEGRATOR) WITH BATCHING

OPTIONAL CUSTOM UNITS OVERLAY W/BACKLIGHT

FOUR SETPOINT ALARM OUTPUTS (W/OPTION CARD)

COMMUNICATION AND BUS CAPABILITIES (W/OPTION CARD)

RETRANSMITTED ANALOG OUTPUT (W/OPTION CARD)

CRIMSON

®

PROGRAMMING SOFTWARE

NEMA 4X/IP65 SEALED FRONT BEZEL

GENERAL DESCRIPTION

The PAX

®

Analog Panel Meters offer many features and performance

capabilities to suit a wide range of industrial applications. Available in five

different models to handle various analog inputs, including DC Voltage/Current,

AC Voltage/Current, Process, Temperature, and Strain Gage Inputs. Refer to

pages 4 through 6 for the details on the specific models. The optional plug-in

output cards allow the opportunity to configure the meter for present

applications, while providing easy upgrades for future needs.

The meters employ a bright 0.56" LED display. The unit is available with a

red sunlight readable or a standard green LED. The intensity of display can be

adjusted from dark room applications up to sunlight readable, making it ideal

for viewing in bright light applications.

The meters provide a MAX and MIN reading memory with programmable

capture time. The capture time is used to prevent detection of false max or min

readings which may occur during start-up or unusual process events.

The signal totalizer (integrator) can be used to compute a time-input product.

This can be used to provide a readout of totalized flow, calculate service

intervals of motors or pumps, etc. The totalizer can also accumulate batch

weighing operations.

The meters have four setpoint outputs, implemented on Plug-in option cards.

The Plug-in cards provide dual FORM-C relays (5A), quad FORM-A (3A), or

either quad sinking or quad sourcing open collector logic outputs. The setpoint

alarms can be configured to suit a variety of control and alarm requirements.

Communication and Bus Capabilities are also available as option cards.

These include RS232, RS485, Modbus, DeviceNet, and Profibus-DP. Readout

values and setpoint alarm values can be controlled through the bus. Additionally,

the meters have a feature that allows a remote computer to directly control the

outputs of the meter. With an RS232 or RS485 card installed, it is possible to

configure the meter using a Windows

®

based program. The configuration data

can be saved to a file for later recall.

A linear DC output signal is available as an optional Plug-in card. The card

provides either 20 mA or 10 V signals. The output can be scaled independent of

the input range and can track either the input, totalizer, max or min readings.

Once the meters have been initially configured, the parameter list may be

locked out from further modification in its entirety or only the setpoint values

can be made accessible.

The meters have been specifically designed for harsh industrial environments.

With NEMA 4X/IP65 sealed bezel and extensive testing of noise effects to CE

requirements, the meter provides a tough yet reliable application solution.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in this

literature or on equipment must be observed to ensure personal safety and to

prevent damage to either the instrument or equipment connected to it. If

equipment is used in a manner not specified by the manufacturer, the protection

provided by the equipment may be impaired.

Do not use this unit to directly command motors, valves, or other actuators

not equipped with safeguards. To do so can be potentially harmful to persons or

equipment in the event of a fault to the unit.

MODEL PAX – 1/8 DIN ANALOG INPUT PANEL METERS

DIMENSIONS In inches (mm)

Note: Recommended minimum clearance (behind the panel) for mounting clip installation is

2.1" (53.4) H x 5.0" (127) W.

Bulletin No. PAX-M
Drawing No. LP0545
Released 02/13