Red Lion PAXDP User Manual

Model paxdp – 1/8 din dual process input meter, Cus listed, General description

Advertising
background image

1

3.80

1.95

.10

4.10

(2.5)

(96.5)

(49.5)

(104.1)

1.75

(44.5)

RST

DSP

PAR F1

F2

A

C

B

1

SP

3

S

2

SP

P

P4

S

8.8.8.8.8

V

(44.5)

1.75

1 2 3 4 5 6 7 8 9 10 11

12
13
14
15

16
17
18
19

20
21
22
23
24
25

3.60 (91.4)

ACCEPTS TWO 4 - 20 mA OR 0 - 10 VDC INPUT SIGNALS

PROGRAMMABLE A/D CONVERSION RATE, 5 TO 105

READINGS PER SECOND

5-DIGIT 0.56" RED SUNLIGHT READABLE DISPLAY

VARIABLE INTENSITY DISPLAY

LINEARIZATION/SQUARE ROOT EXTRACTION INPUT RANGE

PROGRAMMABLE FUNCTION KEYS/USER INPUTS

9 DIGIT TOTALIZER (INTEGRATOR) WITH BATCHING

OPTIONAL CUSTOM UNITS OVERLAY W/BACKLIGHT

FOUR SETPOINT ALARM OUTPUTS (W/OPTION CARD)

COMMUNICATION AND BUS CAPABILITIES (W/OPTION CARD)

RETRANSMITTED ANALOG OUTPUT (W/OPTION CARD)

NEMA 4X/IP65 SEALED FRONT BEZEL

PC SOFTWARE AVAILABLE FOR METER CONFIGURATION

GENERAL DESCRIPTION

The PAXDP Dual Process Input Meter offers many features and performance

capabilities to suit a wide range of industrial applications. Available in two

models, AC or DC power, the meter has the capability to accept two, 4 to 20 mA

or 0 to 10 VDC input signals. Each input signal can be independently scaled and

displayed. In addition, a math function can be performed on the two signals, C +

A + B, C - A - B, C + A - B, AB / C, CA / B, or C (A / B - 1). Any of the three

meter values can have Alarms, Comms, and/or a Retransmitted Analog Output

capability by simply adding optional cards. The optional plug-in output cards

allow the opportunity to configure the meter for current applications, while

providing easy upgrades for future needs.

The update rate of the meter is user selectable. This will help in those

applications where a quick response from the meter is of the utmost importance.

The rate can be adjusted from eight selections with a minimum of 5 updates/

second to a maximum of 105 updates/second.

The meters employ a bright 0.56" (14.2 mm) red sunlight readable LED

display. The intensity of display can be adjusted from dark room applications up

to sunlight readable, making it ideal for viewing in bright light applications.

The meters provide a MAX and MIN reading memory with programmable

capture time. The capture time is used to prevent detection of false max or min

readings which may occur during start-up or unusual process events.

The signal totalizer (integrator) can be used to compute a time-input product.

This can be used to provide a readout of totalized flow, calculate service intervals

of motors or pumps, etc. The totalizer can also accumulate batch operations.

The meter has four setpoint outputs, implemented on Plug-in option cards.

The Plug-in cards provide dual FORM-C relays (5A), quad FORM-A (3A), or

either quad sinking or quad sourcing open collector logic outputs. The setpoint

alarms can be configured to suit a variety of control and alarm requirements.

Communication and Bus Capabilities are also available as option cards. The

standard output is in Modbus Protocol. Any of the following option cards,

RS232, RS485, DeviceNet, or Profibus can be used with the meter. Readout

values and setpoint alarm values can be controlled through the bus. Additionally,

the meters have a feature that allows a remote computer to directly control the

outputs of the meter.

A linear DC output signal is available as an optional Plug-in card. The card

provides either 20 mA or 10 V signals. The output can be scaled independent of

the input range and can track either the input, totalizer, max/min readings, or

math calculation value.

Once the meters have been initially configured, the parameter list may be

locked out from further modification in its entirety or only the setpoint values

can be made accessible.

The meters have been specifically designed for harsh industrial environments.

With NEMA 4X/IP65 sealed bezel and extensive testing of noise effects to CE

requirements, the meter provides a tough yet reliable application solution.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in this

literature or on equipment must be observed to ensure personal safety and to

prevent damage to either the instrument or equipment connected to it. If

equipment is used in a manner not specified by the manufacturer, the protection

provided by the equipment may be impaired.

Do not use this unit to directly command motors, valves, or other actuators

not equipped with safeguards. To do so can be potentially harmful to persons or

equipment in the event of a fault to the unit.

MODEL PAXDP – 1/8 DIN DUAL PROCESS INPUT METER

DIMENSIONS In inches (mm)

Note: Recommended minimum clearance (behind the panel) for mounting clip installation is

2.1" (53.4) H x 5.0" (127) W.

Bulletin No. PAXDP-K
Drawing No. LP0578
Released 11/12

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

CAUTION: Risk of Danger.

Read complete instructions prior to

installation and operation of the unit.

CAUTION: Risk of electric shock.

C

US LISTED

UL

R

51EB

IND. CONT. EQ.