Red Lion CUB5TC User Manual

General description, Safety summary, Dimensions in inches (mm)

Advertising
background image

1

MODEL CUB5TC - MINIATURE ELECTRONIC 5-DIGIT

THERMOCOUPLE

METER

GENERAL DESCRIPTION

The CUB5 provides the user the ultimate in flexibility, from its complete user

programming to the optional setpoint control and communication capability.

The CUB5TC accepts a thermocouple input and provides a temperature display

in Celcius or Farenheit. The meter also features minimum and maximum

display capture, display offset, °F or °C indicator, and programmable user input.

The display can be toggled either manually or automatically between the

selected displays.

The CUB5 display has 0.48" (12.2 mm) high digits. The LCD is available in

two versions, reflective and red/green backlight. The backlight version is user

selectable for the desired color and also has variable display intensity.

The capability of the CUB5 can be easily expanded with the addition of

option cards. Setpoint capability is field installable with the addition of the

setpoint output cards. Serial communications capability for RS232 or RS485 is

added with a serial option card.

The CUB5 can be powered from an optional Red Lion Micro-Line/Sensor

Power Supply (MLPS), which attaches directly to the back of a CUB5. The

MLPS is powered from 85 to 250 VAC and provides up to 400 mA to drive the

unit and sensors.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in this

literature or on equipment must be observed to ensure personal safety and to

prevent damage to either the instrument or equipment connected to it. If

equipment is used in a manner not specified by the manufacturer, the protection

provided by the equipment may be impaired.

Do not use this meter to directly command motors, valves, or other actuators

not equipped with safeguards. To do so can be potentially harmful to persons or

equipment in the event of a fault to the meter.

Bulletin No. CUB5TC-H
Drawing No. LP0643
Released 02/13

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

CAUTION: Risk of Danger.

Read complete instructions prior to

installationand operation of the unit.

CAUTION: Risk of electric shock.

DIMENSIONS In inches (mm)

.13 (3.3)

(43.4)

1.71

2.95 (74.9)

SEL

.15 (3.8)

1.54 (39.1)

RST

(68 )

+.025

-.000

+8

-0

1.29 (32.8)

2.68

-.000

1.30

(33 )

-0

+6

+.024

Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.15" (54.6) H x 3.00" (76.2) W.

C

US LISTED

UL

R

51EB

IND. CONT. EQ.

CONFORMS TO ITS-90 TEMPERATURE STANDARD

COLD JUNCTION COMPENSATION (Enable/Disable)

MINIMUM AND MAXIMUM DISPLAY CAPTURE

LCD, REFLECTIVE OR GREEN/RED LED BACKLIGHTING

0.48" (12.2 mm) HIGH DIGITS

OPTIONAL SETPOINT OUTPUT CARD

OPTIONAL SERIAL COMMUNICATION CARD (RS232 or RS485)

OPTIONAL USB PROGRAMMING CARD

OPERATES FROM 9 TO 28 VDC POWER SOURCE

FRONT PANEL OR CRIMSON PROGRAMMABLE

DISPLAY COLOR CHANGE CAPABILITY AT SETPOINT OUTPUT

NEMA 4X/IP65 SEALED FRONT BEZEL

THERMOCOUPLE INPUTS

Thermocouple types T, E, J, K, R, S, B, N, or mV

PROGRAMMABLE TEMPERATURE OFFSET

SELECTABLE °F or °C WITH 1 or 0.1 DEGREE RESOLUTION

°F OR °C DISPLAY ANNUNCIATORS