4.1 POWER WIRING

INP COMM

USR

+9-28 VDC

INP B

INP A

PWR COMMON

+

-

DC Power

+9 to +28 VDC: +VDC

Power Common: -VDC

4.2 USER INPUT WIRING

INP COMM

USR

+9-28 VDC

INP B

INP A

PWR COMMON

Sinking Logic

INP COMM

USR

The user input of the meter is
internally pulled up to +9 to +28 V
with 10 K resistance. The input is
active when it is pulled low.

Connect external switching device between the
User Input terminal and Input Common.

}

4.3 INPUT WIRING

CAUTION: Power input common is NOT isolated from user input common. In order to preserve the safety of the meter application, the power input

common must be suitably isolated from hazardous live earth referenced voltage; or input common must be at protective earth ground potential. If not,
hazardous voltage may be present at the User Inputs and User Input Common terminals. Appropriate considerations must then be given to the potential
of the user input common with respect to earth ground; and the common of the plug-in cards with respect to input common.

+9-28 VDC

PWR COMMON

INP COMM

USR

INP A

INP B

O.C.

NPN

INP B

INP A

INP COMM

USR

+9-28 VDC

PWR COMMON

Interfacing With TTL

Current Sinking Output

Input A

Switch or Isolated Transistor; Current Sink

Input A

+9-28 VDC

PWR COMMON

USR

INP COMM

INP B

INP A

COMMON

+5 V

4.4 SETPOINT (OUTPUT) WIRING

4.5 SERIAL COMMUNICATION WIRING

COM

N.C.

N.O.

COM

N.O.

N.C.

ELECTRICAL CONNECTIONS

SETPOINT RELAY PLUG-IN CARD

N/C

RS485

2

COMM

A+

B-

N/C

5

3

4

N/C

RS232

5

N/C

TX

N/C

4

3

COMM

COMM

2

RX

6

1

6

1

SERIAL COMMUNICATIONS PLUG-IN CARD

RJ11 CONNECTOR PIN OUTS

Input A

Advertising