Red Lion TMP - FIELD CUTTABLE User Manual

General description, Specifications, Cutting the tubing

Advertising
background image

1

MODEL TMP - FIELD CUTTABLE TEMPERATURE SENSOR PROBES

AND ACCESSORIES

Bulletin No. TMP-F
Drawing No. LP0353
Released 2/09

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

THERMOCOUPLE OR RTD

24" PROBE CUTTABLE TO 3.5"

MEASURE TEMPERATURES UP TO 704 °C/1300 °F

MOUNTING AND WIRING ACCESSORIES

GENERAL DESCRIPTION

Model TMP Thermocouple and RTD Temperature Probes are field cuttable to

the desired length. The probes can be trimmed to within 3.5" (88.9 mm) of the
probe tip allowing for greater application flexibility. Accessory hardware is
available to wire and mount the probes in the user's existing thermowell.

Optional spring loaded fittings (sold separately) slide along the probe sheath

to proper immersion depth as determined by the user. These fittings allow for
strong contact between the probe and the thermowell to improve response.

SPECIFICATIONS

1. THERMOCOUPLE: Ungrounded J, K, T and E calibration available.
2. RTD: 3 Wire, 100

Ω, Class “A” DIN Platinum per IEC751 (385 ALPHA)

3. PROBE SHEATH: 0.25" (6.35 mm)
4. PROBE LENGTH: 24" (0.6 M) as supplied, can be field cut down to 3.5"

(88.9 mm).

5. LEAD WIRE: 6" (152.4 mm) 24 gauge
6. WIRE INSULATION: Neoflon PFA, Fiberglass or High Temperature Glass.

As specified by part number.

CUTTING THE TUBING

The thermocouple and RTD probes have a crimp mark located 3" (76.2 mm)

from the tip. This indicates the end of the internal seal. Damage to the probe will
occur if trimmed within 3.5" (88.9 mm) of the tip.

1. Determine the desired probe length and mark it with a pen or marker. Secure the

probe within a tube vice being careful not to deform or flatten the probe.

2. “Score” the tubing with a tubing cutter. Make one or two revolutions with the

cutter. Do not cut completely through the tubing to prevent burrs or a sharp
lip on the inside of the tubing.

3. Use a pair of pliers to grasp the excess tubing to be removed.
4. Use a narrow range of motion to slowly work the excess tubing from side to

side until it separates from the probe. Using a wide range of motion will
deform the tube and prevent installation of the tube sleeve.

5. Remove the excess tubing and trim the leads to the desired length.
6. Install the tube sleeve in the open end of the tube to protect the leads from any

sharp edges on the inside of the tube.

INSTALLATION

1. Orient the probe and the spring loaded fitting as shown above.
2. Screw the spring loaded fitting one complete turn into the thermowell (not

included).

3. Push the probe into the fitting until it touches the bottom of the thermowell.
4. Hold the probe to the bottom of the thermowell and tighten the fitting. This

ensures good contact between the probe and the bottom of the thermowell.

5. Completely tighten the fitting into the thermowell.

Note: The probe must be inserted only as shown above to prevent damage to

the fitting.

If it becomes necessary to separate the probe and the fitting, first disconnect

the wires and then unscrew the fitting completely from the thermowell. Pull the
probe through the fitting from the end that was screwed into the thermowell. The
fitting will present resistance to the probe removal if you attempt to go in the
wrong direction.

TMPXXXXX

TMPACC01

(One tube sleeve is included with each probe.)

TYPE

MODEL NO.

DESCRIPTION

WIRE

COLOR

WIRE INSULATION

TEMPERATURE RANGE

PART

NUMBER

J

K

T

E

White (+)

Red (-)

Neoflon PFA

0 to 260 °C / 32 to 500 °F

TMPJ2SU1

385

Fiberglass

0 to 370 °C / 32 to 700 °F

TMPJ2SU2

High Temp Glass

0 to 370 °C / 32 to 700 °F

TMPJ2SU3

Yellow (+)

Red (-)

Neoflon PFA

-200 to 260 °C / -328 to 500 °F

TMPK2SU1

Fiberglass

-200 to 482 °C / -328 to 900 °F

TMPK2SU2

TMP

High Temp Glass

-200 to 704 °C / -328 to 1300 °F

TMPK2SU3

TC Probe

Blue (+)

Red (-)

Neoflon PFA

-200 to 200 °C / -328 to 400 °F

TMPT2SU1

Violet (+)

Red (-)

Neoflon PFA

-200 to 260 °C / -328 to 500 °F

TMPE2SU1

Fiberglass

-200 to 430 °C / -328 to 800 °F

TMPE2SU2

High Temp Glass

-200 to 430 °C / -328 to 800 °F

TMPE2SU3

RTD Probe

**

Neoflon PFA

-200 to 260 °C / -328 to 500 °F

TMPA2S01

Fiberglass

-200 to 600 °C / -328 to 1112 °F

TMPA2S02

ORDERING INFORMATION

** RTDs do not have color standard. Excitation and Signal+ are the same color. Signal common is the odd color.