Red Lion PAX2C User Manual

Description, Dimensions in inches (mm), Cus listed

Advertising
background image

1

z

PID CONTROL WITH REDUCED OVERSHOOT

z

UNIVERSAL PROCESS, TEMPERATURE, VOLTAGE, CURRENT

AND RESISTANCE INPUT

z

PROGRAMMABLE DUAL LINE DISPLAY WITH UNITS

INDICATION AND BAR GRAPH

z

FOUR PROGRAMMABLE UNIVERSAL ANNUNCIATORS

z

TRI-COLOR DISPLAY, WITH 7 PROGRAMMABLE COLOR ZONES

z

UP TO 16 ALARMS WITH BOOLEAN LOGIC FUNCTIONALITY

z

BUILT-IN USB PROGRAMMING PORT ENABLING UNIT

CONFIGURATION WITH CRIMSON PROGRAMMING SOFTWARE

z

NEMA 4X/IP65 SEALED FRONT BEZEL

DESCRIPTION

The PAX2C Temperature/Process Controller offers many features and

performance capabilities to suit a wide range of applications. The PAX2C has a

universal input to handle various input signals including Temperature, DC

Voltage/Current and Resistance. Optional plug-in cards allow the opportunity to

configure the controller for present applications, while providing easy upgrades

for future needs. The PAX2C employs a tri-color display with seven

independently programmable color zones.

The controller has been specifically designed for harsh industrial environments.

With NEMA 4X/IP65 sealed bezel, CE compliance and extensive testing of

noise effects, the controller provides a tough reliable application solution.

MAIN CONTROL

The controller operates in the PID Control Mode for both heating and cooling,

with on-demand auto-tune that establishes the tuning constants. The PID tuning

constants may be fine-tuned and then locked out from further modification. The

controller employs a unique overshoot suppression feature, that allows the

quickest response without excessive overshoot. Switching to Manual Mode

provides the operator direct control of the output.

DISPLAY

The PAX2C features a dual line display with units annunciators, dual bar

graphs, four universal annunciators and tri-color capability. Each of the seven

display zones may be configured independently of the others, providing a visual

indication of control and/or alarm status.

ALARMS

The PAX2C has up to sixteen “soft” alarms that may be configured to suit a

variety of control and alarm requirements. These alarms may be used to monitor

and/or actuate the controller’s physical outputs as well as change display colors.

Mapped “soft” alarms may be processed independently or logically combined

using AND/OR Boolean logic.

OPTION CARDS

Optional plug-in cards provide dual FORM-C relays, quad FORM-A, quad

sinking, or quad sourcing open collector logic outputs. These cards can be used

as control outputs or for alarm indication.

A linear DC output signal is available as an optional plug-in card. The card

provides either 20 mA or 10 V signals. The output can be scaled independent of

the input range and can track the input, max and min readings or for control.

Communication and bus capabilities are also available as option cards. These

include RS232, RS485, DeviceNet, and ProfibusDP. The PAX2C can be

programmed to utilize Modbus protocol. With Modbus, the user has access to

most configuration parameters. Readout values, setpoint, process and alarm

values can be controlled through the bus. Additionally, the controller has a

feature that allows a remote computer to directly control the outputs of the

controller.

With a Windows

®

based program, made available by Red Lion Controls,

configuration data can be downloaded to the PAX2C via a built-in USB

programming port.

MODEL PAX2C – 1/8 DIN TEMPERATURE/PROCESS PID CONTROLLER

Bulletin No. PAX2C-B
Drawing No. LP0890
Released 04/13

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

3.80

1.95

0.10

4.14

(96.52)

(49.53)

(2.54)

(105.16)

1.75

(44.45)

3.60

(91.44)

Note: To determine dimensions for

horizontal units, swap height and

width. Recommended minimum

clearance (behind the panel) for

mounting clip installation is:

2.1" (53.4) W x 5.5" (140) H.

DIMENSIONS In inches (mm)

C

US LISTED

UL

R

3RSD

PROCESS CONTROL EQUIPMENT

Advertising