Special instructions for the pmk2a, Method a, Method b – Red Lion PMK2 User Manual

Page 2: Dimensions in inches (mm)

Advertising
background image

Panel Adapter Kit PMK2A is a panel to accommodate CUB2 and provides a

key switch to enable or disable the reset function. Installation for the counter is
identical (See reverse.) Two methods for wiring are provided below to enable or
disable the reset.

METHOD A

This method provides a means of disabling the front panel reset by means of

a key switch. When the key is in the OPERATE position the counter will
operate, but the front panel reset button is inoperative. When the key is in the
RESET MODE position, the counter continues to operate, but the front panel
reset button can be used to reset the counter.

HOOKUP

1. Install counter on plate as described under Mounting. (See reverse.)

2. Push black and yellow wire-lugs (provided with panel kit) on key switch

terminals.

3. Ensure black wire from CUB is in COMMON location and yellow wire from

CUB is in RESET ENABLE location.

4. Twist black wire from key switch together with black wire from CUB with

wire nut provided in accessory bag with CUB.

5. Twist yellow wire from key switch together with yellow wire from CUB with

wire nut provided in accessory bag with CUB.

6. Mount adapter plate into existing panel cut-out.

METHOD B

This method can be used to directly reset the counter with the key itself. With

the key in the OPERATE position, the counter will continue to accumulate
counts. In the RESET MODE position, the counter will reset to zero and remain
there until the key is moved to the OPERATE position.

Note: Do not leave key in RESET MODE position for long periods of time, as

this will drain the batteries at a faster than specified rate.

HOOKUP

1. Install counter on adapter plate as described under Mounting. (See reverse.)

2. Push black and yellow wires with wire lugs (provided with panel kit) on key

switch terminals.

3. Ensure black wire from CUB is in COMMON location.

4. Remove yellow wire from plug. (See CUB1 and 2 Bulletin.)

5. Insert blue wire (supplied with CUB in accessory bag) in REMOTE RESET

location.

6. Twist black wire from key switch together with black wire from CUB with

wire nut provided in accessory bag with the CUB.

7. Twist yellow wire from key switch together with blue wire from CUB with

wire nut provided in accessory bag with the CUB.

8. Mount adapter plate into existing panel cut-out.

Note: Because of the key feature, this panel does not provide a sealed enclosure,

however, the CUB itself will be sealed.

SPECIAL INSTRUCTIONS FOR THE PMK2A

FIGURE 3

METHOD A:
YELLOW TO YELLOW

METHOD B:
YELLOW TO BLUE

DIMENSIONS In inches (mm)

PMK 1

PMK 1A

PMK 1B

PMK 2B

PMK 2A

REPLACES

VEEDER ROOT: 7991 & 7998
DURANT: Series 3000 & 3100
IVO: F129, F514, F518, F524 & F544
SODECO: RG Series

REPLACES

VEEDER ROOT: 1205, 1981, 7443,

7995 & 7997

DURANT: Miniature Electric Series

Y-RMF, Y-MF, YE & 54000

REPLACES

VEEDER ROOT: 1205, 1981, 7443 & 7995
DURANT: Miniature Electric Series

Y-RMF, Y-MF, YE, 3200 & 54000

REPLACES

VEEDER ROOT: 7440
DURANT: Miniature Electric Series

4Y & 6Y, 3000 & 3200

HECON: G0402, G0404 & G0414
IVO: F104, F109, F504 & F574

REPLACES

VEEDER ROOT: 7437 & 7438