2 bellows seal design – ARI Armaturen STEVI 462 EN User Manual

Page 9

Advertising
background image

Rev. 0040307000 0410

Page 9

Operating and installation instructions

Straight through control valves - STEVI

®

422 / 462

7.1.2 Bellows seal design
If the stem leaks, the bellows seal is defective. The leak can initially be stopped by
tightening the sleeve nut (pos. 25.16).
Stem and bellows (pos. 25.3) can only be replaced together.
Replacement of bellows seal:

- Remove actuator.

(Refer to operating instructions for actuator!)

- Loose nuts (pos. 7).
- Detach bellows assembly (pos. 25) incl. stuffing box

housing (pos. 12).

- Slacken screw joint (pos. 25.17) resp. sleeve nut (pos.

25.16) by about one turn.

- Loose nuts (pos. 29).
- Lift bellows housing (pos. 22.1).
- Drive spring pin (pos. 16) out with a drift.

- Unscrew stem adapter (pos. 15) with plug (pos. 8).

- Loose nuts (pos. 25.8).

- Detach mounting bonnet (pos. 25.2) or stuffing box

housing (pos. 25.2).

- Extract stem-/bellows unit (pos. 25.3) from the bellows

housing (pos. 25.1).

- Bolt new parts together and drill them.

- Replace 2 gaskets (pos. 25.6) and 1 gasket (pos. 5).
- Assemble in reverse order.

- Secure with nuts (pos. 7, 25.8 and 29) and tighten them

crosswise.
(For tightening torques refer to item 7.3.1)

- Tighten the screw joint (pos. 22.17) resp. the sleeve nut (pos. 22.16) gradually up to

tightness of the stuffing box packing (pos. 22.10).

ATTENTION !
Refer to item 10.0 and 11.0 before
dismantling the valve.

ATTENTION !
- Ensure that the torsion lock is

correctly positioned when inserting
new stem/bellows unit. Introduce the
grooved pin (pos. 25.9) into the
torsion lock groove.
Make sure it runs smoothly!

Fig. 9: Series 462

Advertising
This manual is related to the following products: