Overview

The AT-PWR14, shown in Figure 1, is an AC redundant power supply (RPS)
used with the AT-CV5000 chassis only. When installed, the module operates
in a standby mode. If the standard power supply fails or loses power, the AT-
PWR14 module changes from standby to active and provides all power to the
system to prevent a network failure.

Figure 1. AT-PWR14 Power Supply Module

Note

The power supply is hot-swappable. You can install it without powering
OFF the AT-CV5000 chassis.

POWER
FAULT

AT-PWR14

208

Related Documents

This installation guide is an abbreviated version of the installation procedure.
For details on the components, features, and functions of this product, refer to
the following documents on our web site, www.alliedtelesis.com:

AT-CV5000 Media Converter Chassis Installation Guide

(PN 613-50580-00)

AT-S70 Management Software User’s Guide (PN 613-50617-00)

Package Contents

Make sure the following items are included in the shipping package. If any
item is missing or damaged, contact your Allied Telesis sales representative
for assistance.

One AT-PWR14 Redundant Power Supply (AC)

This Installation Guide

Warranty Card

Locations of the Power Supply Slots

Figure 2 illustrates the locations of the two power supply modules at the rear
of an AT-CV5000 AC model chassis.

Figure 2. Locations of the Power Supply Slots on the Rear Panel of

an AT-CV5000 AC Model Chassis

Before installing a power supply, please note the following guidelines:

Note

The AT-CV5000 chassis comes with two slots designated for the power
supplies; however, it is shipped with one standard power supply
preinstalled and one empty slot for an optional power supply. The
redundant power supply can be ordered separately from your ATI sales
representative.

Note

Make sure that both power supplies (primary and redundant) are rated for
the same power ratings. For information on the power supply module,
refer to the documentation that is shipped with the module.

Note

The AT-PWR14 power supply can be installed in either one of the power
supply expansion slots while the converter chassis is powered ON. You
do not need to power OFF the chassis to install the power supply.

POWER

FAULT

AT-PWR14

A

B

100-240VAC

~

AT-CVFAN

A

100-240VAC

~

AT-CVFAN

B

214

PS SLOT B - Redundant

PS SLOT A - Primary

Installing the AT-PWR14 Power Supply

To install the AT-PWR14, perform the following procedure:

1. Unpack the new AT-PWR14 module from its shipping container and store

the package material in a safe location.

Note

You must use the original shipping material if you need to return the
power supply module to Allied Telesis.

2. Select the power supply slot in the AT-CV5000 chassis where you want to

install the AT-PWR14 power supply.

3. Make sure that the power switch is in the OFF position.

4. Loosen the two captive screws that secure the blank slot cover

(AT-CV5PNL2) of the selected power supply slot, and remove the blank
slot cover, as shown in Figure 3.

Figure 3. Removing the Power Supply Slot Cover

5. Remove the AT-PWR14 module from its shipping package.

6. Slide the AT-PWR14 module into the RPS slot, as shown in Figure 4.

Figure 4. Inserting the AT-PWR14 Module into the Power Supply Slot

7. Secure the AT-PWR14 module to the AT-CV5000 chassis by using a

Phillips screwdriver to tighten the captive screws, as shown in Figure 5.

Figure 5. Securing the AT-PWR14 Module

211

A

100-2

40VA

C

~

AT-CVFAN

A

100-240V

AC

~

WAR

NING

This u

nit mig

ht have

more t

han on

e pow

er inpu

t. To

reduce

the ris

k of ele

ctric sh

ock, dis

connec

t all po

wer

inputs

before

servic

ing un

it.

209

A

100-2

40VA

C

~

POWER

FAULT

AT-PW

R14

A

WARN

ING

This u

nit mig

ht have

more th

an one

power

input. T

o

reduce

the ris

k of ele

ctric sh

ock, dis

connec

t all po

wer

inputs b

efore s

ervicin

g unit.

212

A

100-2

40VA

C

~

POWER

FAULT

AT-PWR1

4

A

AT-CVFAN

100-2

40VAC~

WARN

ING

This un

it migh

t have m

ore th

an one

power

input. T

o

reduce

the ris

k of ele

ctric sh

ock, d

isconn

ect all

power

inputs b

efore s

ervicin

g unit.

CONVERTEON™

Family

AT-PWR14 Redundant Power Supply (AC)

Installation Guide

Allied Telesis, Inc.

www.alliedtelesis.com

613-50585-00 Rev C

1

2

3

*613-50585-00 Rev C*

Advertising