AMETEK 7250 Digital Stick User Manual

7250 series, 7250x digital stik sensor data sheet

Advertising
background image

AUTOMATION & PROCESS TECHNOLOGIES

®

7250X Digital Stik Sensor Data Sheet

7250 Series

Proven Magnetostrictive Sensing Performance

in a Revolutionary New Package

The 7250X Digital Stik takes f eld proven

magnetostrictive sensing technology

and packages it in a revolutionary new

way for greater reliability and easier

installation and mounting. It is ideal for

liquid level monitoring, interface level and

leak detection in a variety of liquid media

in both above ground and underground

storage tanks.

The 7250X Digital Stik combines low

power consumption with a patented high

resolution design. It requires only 5 volts

DC making it ideal for mobile, battery

operated and wireless applications.

The system has been designed to meet

EPA Leak Detection and API Inventory

Monitoring requirements and has

been approved for use in hazardous

environments.

The sensor’s electronics are SMT

components and integrated into a 5/8”

diameter sensing tube. This breakthrough

design eliminates the bulky electronics

enclosure at the top of the sensor and

offers greater options for insertion and

mounting.

The probe is constructed of 316 Stainless

Steel and comes with a variety of

connectors, including a mini connector

for quick connect applications, a single

3/4” NPT that can be used with a

compression f tting, a double 3/4” NPT for

mounting with a f ange or bushing, and a

1/2” right angle for use in low overhead

applications.

The 7250 communicates through a

single signal. The data is transmitted via

asynchronous serial communications

and is offered with serial protocol options

including an ASCII format. There are

other options available to OEMs for use

in developing a communications interface

with the probe. The patented design

allows for very high resolution on a low

power budget. The resolution of the 7250X

is 0.0001” with a linearity of 0.01% (See

specif cations).

Factory Mutual (FM) certif ed that the

7250X Digital Stik is Intrinsically Safe for

use in ethylene and propane (petroleum)

applications (See specif cations). The

7250X has been approved to the following

standards:

CSA

C22.2 Nos. 25,142,157 and 213

FM

3600, 3610, 3611 and 3810

Cenelec EN 50014, 50020 and 50284

The 7250X has an inherently lower cost

design which results in savings. It provides

the same performance and reliability

as sensors that consume more power.

Combining low power requirements with

high resolution provides the ultimate

performance and reliability.

Specifi cations

Power Supply

Voltage

Current (at +5 VDC)

+5 VDC ± 10% typical (+3.7 VDC min.)

10mA max. (8mA typical) plus

1.5mA max. (1mA typical) per temperature

sensor

Probe Length

Stainless Steel R Style

Stainless Steel D, S, M Style

(Probes available in 1” increments)

21” to 288”

20” to 288”

Consult Factory for

longer lengths

Operating Temperature

Sensing Area

Electronics Area

-40°C to 100°C (Non Hazardous Location)

-40°C to 70°C (Hazardous Location)

-40°C to 70°C

Hazardous Areas Approvals

FM

-40° O Tamb O 70° C

Class I, II, III, Div. 1

Groups C, D, E, F, G, T4

Class I, Div. 2

Groups A, B, C, D, T4

Class I, Zone 0, AEx ia IIB T4

ATEX
Ex ia IIB T4
NEMKO 05 ATEX 1219X

0344

Pressure Rating

Steel Probe: 1000 psi max.

Float: Dependent. Call Factory.

Resolution

0.0001” (Protocol Dependent)

Repeatability

Equal to Resolution

Linearity

Probes up to 288”: ± 0.01% of span

or ± 0.015”, whichever is greater.

Hysteresis

Probes up to 288”: ± 0.002% of span

or ± 0.005”, whichever is greater.

Null Zone

R Style: 9”

D, S and M Style: 8”

Dead Band

2”

Intrinsically Safe Barrier

See Installation Drawing E0241200.

Consult Factory.

Enclosure Material

Rating

316 Stainless Steel IP68

Specifi cations are subject to change without notice. Patented.

II 1G

Sanitary Approvals

(3A 74-03)

 

Advertising