adjustable points on the response curve give the user full flexibility to control non-linear
responses. These functions are adjustable while the controller is running in order to
adjust unknown output characteristics.
* Note – See the DVC710 Programming User Guide for more details.

LOCALIZED CLOSED LOOP FUNCTIONS

All inputs have the ability to be used in a closed loop configuration with the outputs
locally. Most closed loop configurations such as speed and rpm control require very fast
response times. Closing the loop locally, instead of over the CAN Bus on the Master
Module, will result in the response needed for these configurations.

COMMUNICATIONS

A.

The DVC750 has two communication ports:
1

Can Bus 2.0B – This port is used to communicate to other DVC modules
as well as an ECM (engine control module).

2

RS-232 serial port is used for:
i.

Downloading and uploading software.

ii.

Monitoring the functions of the DVC750.

iii.

Setting parameters on the fly (fine-tuning).

POWER SUPPLY

A.

The DVC750 Power Input has the following features:
1

Voltage Input Range

- 8.0Vdc to 32Vdc

2

Reverse polarity protection and transient protection up to 1.5K Watts Peak
Pulse Power Dissipation

3

Multiple power and ground pins must be used if driving over 8 amps (at
one time).



I

NDICATORS

A.

Digital Input Status

(8ea 3mm Green LED)

1

Turns on when the corresponding input is activated. Inputs can be
programmed as active high or low.

B.

High-Side Output Driver Status (6ea 3mm Green LED)
1

Turns on when the corresponding High-side output is activated. Blinks
once per second for an open circuit. Blinks four times per second for a
short circuit.