Pv100 controller, Operating specifications, Pv100 – High Country Tek ProValve 100 Series User Manual

Page 5: Valve controller

Advertising
background image

021-PV100 Rev A

PV100 User Manual

5

Copyright © High Country Tek, Inc.

– 2013

PV100

Valve Controller

PV100 Controller

The ProValve100 controller drives proportional solenoid valves. The output current is proportional to the command
input.

Once configured, the settings are permanently stored in the controller memory.

PV100 Features

Easily configured using HCT Graphical User Interface (GUI) or HCT Hand Held Interface (HHI)

LED indication of power, output current and fault status

DIN-rail mount housing with removable terminal blocks

Multiple modes for single and dual coil applications, programmable enable input

All input and output limits are independently adjustable

Adjustable output with short circuit protection

Operating Specifications

Supply Voltage

12 to 30VDC

Supply Current

Valve current + 50mA (Quiescent Max)

Output Current

Standard: 2.5A max

-L: 500mA MAX

-N: 250mA MAX

Coil Resistance

Standard: 2Ω MIN

-L:

10Ω MIN

–N: 10Ω MIN

Reference Voltages

-10V, +10V @ 2mA

Dither Frequency

35, 41, 49, 61, 81, 122, 244Hz

(Select OFF for PWM frequency 15.63KHz)

Two-speed Ramp Time

0.10 to 16.96 seconds

Analog Slew Time

0.1 to 30.0 seconds

Analog Input Range

[0, 10]V, [-10, +10]V, [0, 5]V, [5, +5]V, [0, 20]mA

Analog Input Impedance

> 100K

for voltage input

500

for current input.

Digital Input Range

-24: 12 to 30VDC

-115: 100 to 130VAC

-230: 210 to 250VAC

Digital Input Impedance

-24: 3.3k

-115: 33k

-230: 75

Operating Temperature Range

0º to 70º C (operating); -40º to 85º C (storage)

Enclosure

Compact

Dimensions

Inch: 3.9 L x 4.5 W x 0.4 H, Mm: 99 L x 114.5 W x 10 H