6

h) DIP switch

DIP switches are “ON” when down and “OFF” when up. The default setting is with all switches set OFF (up).

The table below describes their effect.

**In a system with only a single MULTIzone unit, if DIP switch 5 is set ON then any microphone signal will “duck” the music signal in

whichever zone(s) the microphone level is set above zero – but the microphone signal will not be heard.

i) Remote Zone Controller inputs

Four RJ-45 sockets for connection to remote Zone Control wall plates. Connect via an 8-way CAT-5 cable terminated with RJ-45

plugs at each end for each Zone. The Zone Control wall plate takes over control of Zone input select and volume control – disabling

the front panel controls for that zone. See Appendix 2 for further details.

j) RS-232 control input

9-pin male “D-type” connector. See Appendix 4 for further details and the RS-232 control protocol.

j

i

h

SW

Function

DIP switch UP

DIP switch DOWN

Notes

OFF

ON

1 RS-232 Address LSB

0

1

Use these switches to set the “unit number”

for RS-232 addressing. See Appendix 4 for

details.

Set all three switches to “0” (UP) to lock the

unit into Manual mode – disabling all RS-232

control.

2 RS-232 Address

0

2

3 RS-232 Address MSB

0

4

4 RS-232 source –

when unit is SLAVE

Unit is controlled from

local RS-232 socket

RS-232 control from

LOOP input

When unit is master, RS-232 signal is sent to

LOOP out – so DIP switch has no effect.

5 MIC source –

when unit is SLAVE

Local microphone “ducks”

unit’s Zone outputs

Master (LOOP) microphone

“ducks” unit’s Zone outputs

When unit is master, ducking signal is sent to

LOOP out – so DIP switch has no effect. **

6 Phantom Power

off

on

Phantom power to microphone

7 Zone 1 Audica EQ

off

AEQ

Audica speaker EQ

is designed to optimise

performance from Audica Pro loudspeakers.

If Audica Speaker EQ is to be used in a system

with a subwoofer, please refer to Appendix 5.

8 Zone 2 Audica EQ

off

AEQ

9 Zone 3 Audica EQ

off

AEQ

10 Zone 4 Audica EQ

off

AEQ