Required tools and installations equipment
Depending on type of installation, the following tools are required:
-set of screw drivers
-drill and set of bits
-wrench
-crimping shears for the12/24V wire connection
For connection of inverter to the battery, the following cable connecting
hardware is needed:
-2 different flexible cable connections.
-Various terminals, multi-core cable ends

Caution:
Before drilling any mounting holes, make sure that there are no wires,
fuel lines or tanks directly below the surface being drilled.

Installation
The inverter has to be installed in a dry and clean place not being
exposed to humidity.
Make sure there is proper ventilation.
Keep at least a free space of 10 cm surrounding the inverter.
If installed into housing, make sure there’s good ventilation.
The air intake on the bottom of the inverter and the air outlet on the back
side may not be blocked.
In case of ambient temperatures of more than 35C (e.g. engine or
heating room, direct sunlight), the inverter will switch off automatically,
because of self heating effects during operation.
The installation surface must be balanced and sufficiently strong.

Installation of the inverter

-Adjust the inverter to the chosen installation place and mark the fixing
points.
-Fix the inverter by using the self chosen fixing method.

Electrical connection
General instructions for electrical connection.
In case of the inverter is installed into vehicles or boats it has to be
connected to the chassis (ground).
If cables have to be inserted to metal walls or other sharp-edged means,
use a cable duct or cable bushes.
Do not pull the cables.
Do not lay cables loose or in sharp bends on electrical conducting
materials (metal).
Do not lay 110V mains cable and 12/24 VDC cable together into the
same cable duct.
The specified minimum cable cross section must be complied with.
Secure cables properly.