3 injectors replacement, 4 adjustment of minimum level – Electrolux EGG7253NOX User Manual

Page 13

Advertising
background image

come in touch with mobile parts or they

are not squeezed. Also be careful when

the hob is put together with an oven.

Make sure that the gas

supply pressure of the

appliance obeys the

recommended values.

If the supplied pressure has not the

specified value, it is necessary to

assemble a proper pressure regulator in

compliance with the standard UNI EN 88.

For Liquid Gas (LPG) the use of pressure

regulator is allowed only if they are in

compliance with UNI EN 12864. The

adjustable connection is fixed to the

comprehensive ramp by means of a

threaded nut G 1/2". Screw the parts

without force, adjust the connection in the

necessary direction and tighten

everything.

A

B

C

A) End of shaft with nut

B) Washer

C) Elbow (if needed)
Rigid connection:

Carry out connection by using metal rigid

pipes (copper with mechanical end) (UNI-

CIG 7129).
Flexible connection:

Use a flexible pipe in stainless steel (UNI-

CIG 9891) with a maximum length 2 m.

WARNING!

When installation is complete,

make sure that the seal of

each pipe fitting is correct.

Use a soapy solution, not a

flame!

8.3 Injectors replacement

1. Remove the pan supports.

2. Remove the caps and crowns of the

burner.

3. With a socket spanner 7 remove the

injectors and replace them with the

ones which are necessary for the type

of gas you use (see table in "Technical

Information" chapter).

4. Assemble the parts, follow the same

procedure backwards.

5. Replace the rating plate (it is near the

gas supply pipe) with the one for the

new type of gas supply. You can find

this plate in the package supplied with

the appliance.

If the supply gas pressure is changeable

or different from the necessary pressure,

you must fit an applicable pressure

adjuster on the gas supply pipe.

8.4 Adjustment of minimum level

To adjust the minimum level of the

burners:
1. Light the burner.

2. Turn the knob on the minimum

position.

3. Remove the knob.

4. With a thin screwdriver, adjust the

bypass screw position (A).

A

5. If you change:

• from natural gas G20 20 mbar to

liquid gas, fully tighten the bypass

screw in.

• from liquid gas to natural gas G20

20 mbar, undo the bypass screw

approximately 1/4 of a turn (1/2 of

a turn for Triple Crown burner).

ENGLISH

13

Advertising