Gun library & information screen, Gun information screen (cont.) – Kestrel 4500NV Applied Ballistics Meter User Manual

Page 13

Advertising
background image

13

Gun lIBRARy & InFORMATIOn sCREEn

MV-Temp Table

This allows you to enter and maintain a table of muzzle

velocities based on temperature. If an entry is input

into the table, the muzzle velocity is applied at all

temperatures (this means that the value is then locked

and cannot be altered by using

and on the gun

information screen). If two or more entries are input into

the table, the Kestrel uses the linear interpolation and

the temperature sensor to determine the appropriate

muzzle velocity. (Note: this value will only change if

the temperature changes and you exit and re-enter

the gun information screen; once a muzzle velocity

value is entered for a particular temperature, you can

not make another muzzle velocity value for the same

temperature.)

• To access MV-Temp table, scroll to MV (Muzzle

Velocity) to highlight it and press

, then use

to scroll to MV-Temp and press

to enter.

• Press

while “New entry” is

highlighted to enter the Table

Item screen.

• Use

or

to scroll to

“Temp” and “MV.” Use

and

to adjust each value.

• To clear a Table Item, scroll

down to Clear and

press

.

• Press to exit to return to the

Gun Information

screen.

Drag Curves

The Kestrel with Applied Ballistics allows you to use G1 or

G7 drag curve model, or AB's custom drag curves.

• To select the appropriate drag curve, scroll to "DC."

• Use and to scroll through options.

• If a custom drag curve is used, no further adjustment is

necessary. If using G1 or G7 drag curves, you must adjust

the BC by scrolling down and editing to the proper value.

For more information on the custom drag curves, please see

page 18.

Calibrate Muzzle Velocity

This allows you to calibrate your muzzle velocity based

on the actual drop of a round at a range where the bullet

is supersonic. With the range and the drop entered, the

Kestrel automatically adjusts muzzle velocity to match.

• To access the muzzle velocity Cal, scroll to Cal MV to

highlight it and press

.

MV
feet

p

er sec

MV-Tem

p

Muzzle velocity

2900

f

p

s

Tem

p

MV
Clear

Table item

10ºF

2900

f

p

s

Gun InFORMATIOn sCREEn (COnT.)

MV Cal

1398m

Range

1275m

Drp

9.35mil

-Cal
MV

2826fps

The number shown to the top right

of the screen is the suggested range

distance at which to calibrate

muzzle velocity. This range is

calculated from when the bullet is

at a speed of Mach 1.2.

• Use and to adjust the range at which you are

firing. The Drop will update with the range.

• Use

to scroll to “Drp.” Use and to adjust the value

to match the observed drop of the bullet at range.

• Use

to scroll to “Cal" and press

. The Calculated

Calibrated Muzzle Velocity value will be displayed at the

bottom of the screen.

• Press to exit to return to the Gun Information

Advertising