Acknowledge), and Lamp Test may be accomplished through

special key- or push-switches.

Agency Listings and Approvals

These listings and approvals apply to the modules specified in

this document. In some cases, certain modules or applications

may not be listed by certain approval agencies, or listing may

be in process. Consult factory for latest listing status.

UL Listed: S635

ULC Listed: S635

MEA Listed: 291-61-E Vol. 4 (System 500, LDM-R32);

289-91-E Vol. V (AM2020/AFP1010); 104-93-E (AFP-200);

17-96-E (AFP-300/400); 447-99-E (AFC-600)

CSFM: 7120-0028:0156, 7165-0028:0224 (NFS-3030,

NFS2-3030); 7170-0028:0223 (NFS-3030, NFS2-3030)

BSA: 578-81-SA (System 5000, System 500 except

LDM-R32)

FM Approved

City of Chicago approved: Class 1, Class 2

City of Denver approved

FDNY COA #6085 (NFS2-640); 6065 (NFS2-3030)

Product Line Information

LDM-32: Lamp Driver Module with 32 alarm lamp-driver tran-

sistors (sink to power common on alarm). May be selected

(dip switch) for 16 alarm/circuit on, 16 trouble, and 16 switch

inputs if desired. Also includes system-trouble lamp driver and

lamp-test/local-acknowledge switch input. Integral piezo

sounder sounds for each new alarm or trouble and is silenced

with the Local Acknowledge switch, or permanently disabled

with a dip switch selection. Flash of new alarms or troubles is

selectable through dip switches. 16 switch inputs may be used

for panel SILENCE, RESET, or remote relay control. Instruc-

tions are included.
LDM-E32: Lamp Driver Module with 32 alarm drivers; or 16

alarm, 16 trouble, and 16 switch inputs. One LDM-E32 is

allowed per LDM-32 in alarm-only mode. Three LDM-E32

modules are allowed per LDM-32 in alarm/trouble. Includes

ribbon cable to connect to LDM-32/LDM-E32.
LDM-R32: Lamp Driver Module which connects to any LDM-

32 or LDM-E32 to convert transistor outputs to 32 Form-A dry

contacts (1.0 A @ 30 VDC). Provides 32 output terminal

screw connections and a single common terminal screw.

Includes ribbon cables to connect to the LDM-32/LDM-E32.

Use for electrical isolation when interfacing the system to other

equipment.
LDM-CBL24, LDM-CBL48: Ribbon cable sets to provide

either a 24” (60.96cm) or 48” (121.96cm) connection between

LDM-32/LDM-E32 and LEDs or lamps on a custom graphic

panel. Includes all cables necessary for one LDM-32 or

LDM-E32. Cables have connector on one end only (split, strip,

and connect other end to graphic annunciator).

Architectural/Engineering
Specifications

For specifications on LDM Graphic Annunciator Lamp Driver

Modules, contact NOTIFIER.

LDM-E32

LDM-R32

LDM-CBL48
LDM-CBL24