• Maximum current charge: 1.5 A.
• Maximum battery capacity: 18 AH.

Applications

Example 1: Expand notification appliance power an additional

6.0 A (FCPS-24S6) or 8.0 A (FCPS-24S8). Use up to four

Class B (Style Y) outputs or four Class A (Style Z) outputs

(using ZNAC-4). For example, the FACP notification appliance

circuits will activate the FCPS when reverse-polarity activation

occurs. Trouble conditions on the FCPS are sensed by the

FACP through the notification appliance circuit.
Example 2: Use the FCPS to expand auxiliary regulated 24-

volt system power up to 4.0 A (FCPS-24S6) or up to 6.0 A

(FCPS-24S8). Both resettable and non-resettable power

options are available. Resettable outputs are created by con-

necting the resettable output from the FACP to one or both of

the FCPS inputs.
Example 3: Use addressable control modules to activate the

FCPS instead of activating it through the FACP notification

appliance circuits. This typically allows for mounting the FCPS

at greater distances* away from the FACP while expanding

system architecture in various applications.
For example, an addressable control module is used to acti-

vate the FCPS, and an addressable monitor module is used to

sense FCPS trouble conditions. Local auxiliary power output

from the FCPS provides power to the addressable control

module.

*NOTE: Addressable FACPs are capable of locating control and
monitor modules at distances of up to 12,500 feet (3,810 meters).

Sync Follower/Generator Note

In some installations, it is necessary to synchronize the flash

timing of all strobes in the system for ADA compliance.

Strobes accomplish this by monitoring very short timing pulses

on the NAC power which are created by the FACP. When

installed at the end of a NAC wire run, the FCPS-24S6/-24S8

can track (i.e. “follow”) the strobe synchronization timing

pulses on the existing NAC wire run. This maintains the overall

system flash timing of the additional strobes attaches to the

FCPS.
When the FCPS-24S6/-24S8 is configured (via DIP switch set-

tings) as a “sync follower,” the FCPS’s NAC outputs track the

strobe synchronization pulses present at the FCPS’s sync

input terminal. The pulses originate from an upstream FACP or

other power supply.
When the FCPS-24S6/-24S8 are configured (via DIP switch

settings) as a “sync generator,” the FCPS’s sync input termi-

nals are not used. Rather, the FCPS is the originator of the

strobe synchronization pulses on the FCPS’s NAC outputs. In

“sync generator” mode, the sync type (System Sensor, Whee-

lock, or Gentex) is selectable via DIP switch settings.

Standards and Codes

The FCPS-24S6 and FCPS-24S8 comply with the following

standards:

NFPA 72 National Fire Alarm Code.

UL 864 Standard for Control Units for Fire Alarm Systems

(NAC expander mode).

UL 1481 Power Supplies for Fire Alarm Systems.

Agency Listings and Approvals

These listings and approvals apply to the modules specified in

this document. In some cases, certain modules or applications

may not be listed by certain approval agencies, or listing may

be in process. Consult factory for latest listing status.

UL Listed: S635, S674

ULC Listed: S635 (FCPS-24S6C & FCPS-24S8C)

CSFM Approved: 7315-0028:225

MEA: 299-02-E

• FM Approved

Ordering Information

FCPS-24S6: 6.0 A, 120 VAC remote charger power supply.

Includes main printed circuit board, transformers, enclosure

(15”H x 14.5”W x 2.75”D [cm: 38.1H x 36.83W x 6.985D]), and

installation instructions.
FCPS-24S6C: Same as above, ULC-listed.
FCPS-24S6R: Same as FCPS-24S6 with red enclosure.
FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply.

Includes main printed circuit board, transformers, enclosure

(15”H x 14.5”W x 2.75”D [cm: 38.1H x 36.83W x 6.985D]), and

installation instructions.
FCPS-24S8: 8.0 A, 120 VAC remote charger power supply.

Includes main printed circuit board, transformers, enclosure

(15”H x 14.5”W x 2.75”D [cm: 38.1H x 36.83W x 6.985D]), and

installation instructions.
FCPS-24S8C Same as above, ULC-listed.
FCPS-24S8R: Same as FCPS-24S8 with red enclosure.
FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply.

Includes main printed circuit board, transformers, enclosure

(15”H x 14.5”W x 2.75”D [cm: 38.1H x 36.83W x 6.985D]), and

installation instructions.
ZNAC-4: Class A (Style Y) NAC option module.
EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire

smoke detector power.
BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT

Series data sheet DN-6933).
PS-1270: Battery, 12-volt, 7.0 AH (two required, see PS

Series data sheet DN-1109)