The 201T gas
detection transmitter
is designed to meet
or exceed safety
requirements in a
variety of commercial
and industrial
applications.

User Friendly

10-step LED display

Proven sensing technology

Easy installation and operation

Reliable

Field-proven protection

Robust RS-485 Modbus communication

Versatile

Stand-alone or network configuration

Full compatibility with the Vulcain 301C

controller

Original Architecture

Innovative and compact case design

Beneficial Options

Optional 4-20 mA and one relay output

Optional audible alarm and LCD display

General Specification

Uses

Work horse transmitter of a gas detection network to be used with the 301C controller providing a cost-effective solution to gas related hazards and energy
management

Power Requirement 7-27 VAC, 24-38 VDC, 250 mA

Size

8.4 x 5.3 x 2.25 in. (21.3 x 13.4 x 5.7 cm)

Weight

0.88 lb (0.4kg)

Display

10-step LED or LCD

Visual Indicators

Failure Indication: Yellow LED (Available in network configuration only)
Normal Operation: Green LED

Relay Output
Rating

5A, 30VDC or 250 VAC (resistive load)

Audible Alarm

65 dBA at 3 ft. / 1 m

Optional Outputs

RS-485 Modbus, 4-20mA, Alarm relay

Sensing Technology

Q1-type Sensor

Toxic: Electrochemical
Combustibles: Catalytic
Oxygen: Diffusion fuel cell

Q2-type Sensor

Refrigerants: Solid-state
Carbon Monoxide: Electrochemical

Detection

Gas Detected

Detection Range

Accuracy

Operating Humidity Range

Operating Temperature Range

Q1

Q2

Q1

Q2

Q1

Q2

Q1

Q2

Carbon Monoxide (CO) 0-50 ppm

0-100 ppm
0-250 ppm (std)
0-500 ppm

0-250 ppm

+/- 3%

+/- 5%

0 - 90% RH
non-condensing

10 - 95% RH
non-condensing

-4 to 122°F
(-20 to +50°C)

-4 to 122°F
(-20 to +50°C)

Nitrogen Dioxide (NO

2

)

0-10 ppm

+/- 3%

15 - 90% RH,
continuous

-22 to 122°F
(-30 to +50°C)

Oxygen (O

2

)

0-1 ppm

+/- 3%

5 - 95% RH,
continuous

-4 to 131°F
(-20 to +55°C)

Combustibles

0-100% LEL

+/- 3%

+/- 5%

0 - 95% RH,
non-condensing

4 to 104°F
(-10 to +40°C)

Refrigerants (R134a)

0-2000 ppm

+/- 10%

40 - 100% RH,
non-condensing

32 to 122°F
(0 to +50°C)

Ratings and Certifications:

Certified to

CAN/CSA C22.2 No. 61010-1

116662

Conforms to

ANSI/UL 61010-1

The 201T series transmitters are
able to detect a wide range of toxic
and explosive gases. The 201T gas
detection transmitter can work in an
addressable network mode with the
301C controller through an RS-485
Modbus link. They can also be used
in a stand-alone configuration with
an optional 4-20mA or alarm relay
outputs.

The catalytic sensors of the 201T
can be used to detect hundreds of
different gasses and inflammable
vapour concentrations. Toxic
gasses are detected by way
of electrochemical cells, while
metal-air battery cells are used to
detect oxygen. Moreover, a second
generation of semi-conductor
detectors offer a highly effective
solution for a variety of different
applications.