General specification – Notifier Lumidor Minimax XT User Manual

Page 3

Advertising
background image

General Specification

Standard Specification

General

Disposable single gas monitor for the protection of personnel against toxic and Oxygen gas hazards

Maximum Operating Life

2 years after activation

Shelf Life

12 months before activation (CO and H

2

S), 6 months before activation (O

2

)

Sensor Range

Carbon Monoxide CO

0 to 1000 ppm (display: 0-200 ppm)

Hydrogen Sulphide H

2

S

0 to 100 ppm (display: 0-100 ppm)

Oxygen

O

2

0 to 30%v/v (display: 0-25.0%v/v)

Alarm Set Points

CO

35 ppm

100 ppm

(Note: Other alarm settings

H

2

S 10

ppm

15

ppm

are available upon request)

O

2

23.5%

19.5%

Calibration CO/H

2

S Zero

adjustment

(optional

Span)

O

2

Span

adjustment

Operating Temperature

-4°F to +122°F (-20°C to +50°C)

Humidity

5-95% RH (non-condensing)

Audible Alarm

95db at 4in (10cm)

Visual Alarm

High intensity red LEDs

Vibrating Alarm

Supplied as standard

Display Custom

LCD

Sensor Type Electrochemical

Battery

3.6V non-replaceable Lithium battery

IP Rating

IP67 (NEMA 4 & 6)

Intrinsic Safety

Europe: II 2G EEx ia IIC T4 (ATEX)

UL/cUL: Class 1, Div 1, Groups A, B, C, D T4

RFI/EMC

CE EN50270:1999 and EN55011

Dimensions

3.4"(H) x 2"(W) x 1.1"(D)

(87mm x 50mm x 27mm)

Weight CO/H

2

S 73g

(2.57oz)

O

2

82.3g

(2.90oz)

*Reflex

TM

not available for all sensors

Display Details

Test pass icon

Level 2, CO, H

2

S

Level 1, CO, H

2

S, O

2

Level 2, O

2

Life time: Months, days, hours

Concentration units

Low peak

High peak

Test Fail icon

Life time, alarm reading

Battery

1 l

ev

e

L

2 l

ev

e

L

* Oxygen detection products must only be used
to detect oxygen depletion in air.